Construction-site exposure monitoring scope, WTC, Oct 2001

Machine-extracted title · confidence 32%

Scope of personal exposure monitoring for hazards at the WTC project, including sampling and data reporting.

NYC-WTC_000429602
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

<1 ATTACHMENT 1

SCOPE OF SERVICES

GENERAL

ATC will conduct personal exposure monitoring for physical and chemical hazards including air contaminants (dust, metals, volatile organic compounds, and other specific compounds) heat .stress, cold stress and noise as directed by BECHTEL.

ATC shall provide BECHTEL a list of samples collected and any direct reading instrument results at the beginning of the next day in accordance with the format shown in Table 3. BECHTEL will present accumulated data to the various agencies as requested. ATC will not release any data to agencies or other person(s) without written approval from BECHTEL.

ATC will supply the following information to BECHTEL: (1) Identification of analytical laboratory including certifications, (2) Qualifications of contractor project manager (3) Quality assurance plan (4) List of proposed sampling equipment and instruments (5) Time and material rates for sampling technician, sampling equipment, use rates, and lab sample costs (based on 24-hour report of results). Site Conditions The work schedule at the World Trade Center (WTC) project is 24 hours a day, 7 days a week but this schedule may change. Sampling may be required at any time. Project duration is unknown at this time. Initially, sampling will be conducted in accordance with the Sample Monitoring Plan (Table 1) but the schedule, craft personnel to be sampled, analytes, and number of samples collected may change based on sampling results and/or planned tasks. The crafts and contractors to be sampled will be determined in coordination with BECHTEL using the daily WTC project personnel logs or other available information.

ATC must comply with all WTC Disaster Project site provisions and security requirements. Direct Reading Exposure Monitoring The following are some of the instruments that may be required for exposure monitoring. » Photo-ionization detector, (PID) » Flame-ionization detector (FID) • Combustible gas indicator (CGI) • Specific gas monitors (e.g., oxygen, carbon monoxide, hydrogen sulfide) » Direct reading CO with data logging » Real-time aerosol monitor /RAM) or Dust Trak • Radiation detection instruments • Colorimetric indicating tubes (e.g., Draeger tubes) e Mercury vapor analyzer • Infrared analyzers (MIRAN) * Noise dosimeter • Sound level meter (SLM) (Tmc ■ cadir g monitoring results (date/time, calibration information, results, and activities momtored) shall be recorded initially and periodically throughout the monitoring period (e.g..

04,003095

CITY_21MC100_003077167

NYC-WTC_000429602

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000429602Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000280660

Additional pages for the WTC health monitoring and sampling RFP, city file reference.

Similar indexed content

Compare copies and versions →