NYC 9/11 Public Portal Document
Ambient Air Monitoring Program Section No. 10
Quality Assurance Project Plan Revision No.: 0
130 Liberty Street - NY, NY Date: August 2005
Lower Manhattan Development Corporation Page 52 of 116
10.0 FIELD MONITORING REQUIREMENTS
10.1 Monitoring Process Design
Refer to Section 7.1.1 for the monitoring design of this project. This section discusses the areas
being sampled, what is being tested, and how often.
10.1.1 Meteorological Data Collection
Potential sources of variability may be due to meteorological data. Due to the complex nature of
wind movement in an around buildings in the urban setting of Lower Manhattan, monitoring of
wind velocity and direction on a continuous basis is warranted. Data available from regional
National Weather Stations (NWS) such as Newark Airport, LaGuardia and Kennedy Airports
can be used to complement the localized data but it is likely NWS data may not always be
representative of conditions in and around the 130 Liberty Street site. A meteorological station
will be deployed in the immediate vicinity of the site. The actual station will initially be located
at roof top level at the deconstruction site (130 Liberty Street).
Data from the roof top station will be logged continuously at the unit’s data logger and also
transmitted via cellular modem to the street level computer station.
The meteorological monitoring component of the air sampling and monitoring program will
consist of equipment designed to continuously record wind speed, wind direction, standard
deviation of wind direction, and air temperature from a roof mount tower. Monitoring will be
done from the roof of the building at 130 Liberty Street until deconstnjction activities warrant its
physical removal when the roof is removed or access is denied due to ongoing construction
activities. The 130 Liberty Street roof-mounted station will then be collocated with one of the off
site rooftop air monitoring stations.
10.2 Monitoring Methods
The following sections provide a brief description of the sampling procedures to be employed for
each parameter and a summary of the required equipment.
10.2.1 Metals (TSP Filters)
Total suspended particulate (TSP) samples to be analyzed for metals will be collected employing
high-volume air sampling techniques in accordance with US EPA standard reference method 40
CFR Part 50 Appendix B, Reference Method for the Determination of Suspended Particulate
Matter in the Atmosphere (High-Volume Method). Samples will be collected over an estimated
twenty-four hour sampling period. During this period ambient air will be collected at a flow rate
of approximately 1 m/minute. Numbered, preweighed quartz fiber filters provided by the
subcontracted laboratory will be placed in each sampling system prior to the start of each
sampling event. The air sampler draws approximately 1200-1500 m^ through the filter during
L2005-346 Rev. 1
C ITY_D E P_WO RB Y_C AN N ATA_SU B P_000114693
NYC-WTC_000428376
OCR can misread numbers and units. Confirm readings against the page image before using them.