Silica Analysis, EMSL Order 040305286

Machine-extracted title · confidence 40%

X-ray diffraction silica analysis performed under EMSL order 040305286 for NYC DEP project.

NYC-WTC_000428139–000428141
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

EMSL Analytical, Inc. 107 Haddon Ave., Westmont, NJ 081 OS

EMSL Order 10:040305286 Attn: Andrew/ M N. Khan Customer ID: JLCC50 JLC Environmental Consultants, Inc. Customer PO; 200 Park Ave South, Suite 1001 Date Received: ' 04/05/03 12:23 AM New York, NY 10003 Fax: 212-420-6092 EMSL Order: 040305286 Project: #03-2744/NYCDEP—114 Liberty ST EMSL Project ID: Report Date: 04/14/03 Date Analyzed; 04/14/03

Silica, Crystalline Analysis Performed X-Ray Diffraction (XRD) Modified NIOSH Method 7500, Issue 3,1/15/98

j Respirable Dust Airborne Silica Sample Sample Silica Silica .% Analytical Sample ID Identification Particle Volume Weight Cone. Weight Cone. Silica Sensitivity ID (L) (mg) (mg/m’) (mg) (mg/m’) (mg/m’)

MB 13687-1 12THFLR SOUTH Quartz 408 <0.002 N/A <0.0045 <0,0110 N/A 0.0110 MB 13687-2 1ITH FLR DINING Quartz 408 <0.002 N/A 0.0090 0.0221 N/A 0.0110 MB 13687-3 lOTHFLR DINING Quarte 408 0.601 1.4730 0.0080 0.0196 1.3 0.0110 MB 13687-4 9TH FLR DINING Quartz 408 0.014 0.0343 0.0090 0.0221 64.3 0.0110 MD 13687-5 STII FLR DINING Quartz 408 <0.002 N/A <0.0045 <0.0110 N/A 0,0110 MB13687-6 7TH FLR DINING Quartz 408 0.010 0.0245 <0.0045 <0.0110 45.0 0.0110 MB13687-7 6TH FLR DINING Quartz 408 0.090 0.2206 <0.0045 <0.0110 5.0 0.0110 MB 13687-8 STH FLR DINING Quartz 408 <0.002 N/A <0.0045 <0.0110 N/A 0.0110 4TH FLR MB13687-9 KITCHEN Quartz 408 0.115 0.2819 <0.0045 <0.0110 3.9 0.0110

Disclaimer: The laboratory can only verily the concentration of silica on the filter and not the final concentration due to data obtained by non-laboratory personnel. In the absence of a bulk dust sample, neither the specific forms of crystalline silica nor the interfering species can be fully determined. Hence, the amount for each phase, if anticipated, will be analyzed based on primary, secondary, and/or tertiary peak data with comparison to calibration curves of known standards. It should be noted that air samples are meant for only quantifying silica (or a mineral phase) which must first be identified from a bulk dust sample. “<” means less than the stated value. The lowest reportable value is equivalent to the Analytical Sensitivity that is calculated from the lowest reprndncthle amraint of specific mineral detectable by the inEtmment.

Anant Samndra, Ph.D. Analyst Steph^en Siegel, Cllf- I^b Manager Or other approved signatory

AIHA Accredited - Laboratory ID #100194 Pagel of 3

1

CITY_DEP_WORBY_CANNATA_SUBP_000113886

NYC-WTC_000428139

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000428139Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →