NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 110 pages

QA/QC Plan, Environmental Monitoring Program

Machine-extracted title · confidence 54%

Quality Assurance Project Plan for Environmental Community Air Monitoring and Waste Management at Greenwich sites.

NYC-WTC_000427900–000428009
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - September 29, 2005

higher magnifications of 10,000 and 20,000x used as needed for precise measurements and identification of individual fibers. Only PCME fibers (both asbestos and non­ asbestos) are recorded. Fibers that intersect a grid bar will be recorded as % fiber but only if the visible portion is a least 2.5 microns in length. As with the AHERA analysis, identification of asbestos will be performed by a combination of morphology, SAED, and EDXA. Enough grid openings will be analyzed during this phase of analysis to reach a project-specific target analytical sensitivity of less than 0.0009 libers cm3. In addition, samples may also be analyzed using Scanning Electron Microscopy (SEM) due to the potential overloading problem with TEM which may be caused by excess particulates. This will be determined on a sample-specific basis and performed as needed. SEM is a wellestablished methodology that utilizes a scanning electron microscope. The SEM can work in many different magnification ranges from lOOx to 20,000x. The sample preparation is different than TEM, whereas samples are gold coated and mounted on a stub, with minimal degradation to the original sample. The SEM is more flexible with regard to types of material you can introduce into the chamber. SEM can achieve much better contrast than TEM and results in almost a 3-D image whereas the TEM is a 2-D “shadow”. SEMs are typically equipped with Energy Dispersive X-Ray analyzers (EDXA) just like TEM. This enables the analyst to determine the elemental composition of a material or fiber observed. The SEM is not equipped with Electron Diffraction capabilities unlike the TEM, which allows the analyst to determine the crystal structure of a mineral based on a distinct pattern of spots that is produced from the bombardment of an electron beam. Selected Area Electron Diffraction (SAED) is cited in many TEM methods including AHERA and is required to yield a definitive asbestos identification. For this project, however, since the dust has been so well characterized, the need for SAED is not as essential.

11.1.2.4 Metals Analysis by SW-846 Method 6020A

Metals analysis will be performed using SW-846 Method 6020A with the following modifications:

• Samples will be digested using nitric acid as per 40 CFR Part 50 Appendix J, not a mixture of nitric and hydrochloric acid. Sample digestion will be performed using a hotplate or Modblock digestion procedure. • Initial ICP/MS instrument calibration will be performed using a blank and a single-point standard. • The routine calibration procedure will not include the analysis of a High Standard Verification (HSV) standard. Calibration will be verified with the CCB and CCV. • The laboratory will perform the metals analysis by scanning the selected ion, not scanning all ions from 5-250 amu. • The internal standard mixture used by the laboratory will include Li, Ge, In, Tm, and Bi.

11.1.2.5 PCB Analysis

61

CITY_DEP_WORBY_CANNATA_SUBP_0001 01712

NYC-WTC_000427960

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427960Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000423885

Quality Assurance Project Plan for environmental air monitoring and waste management at Greenwich and Thames sites; Sept 30, 2005.

Similar indexed content

NYC-WTC_000451195

QA plan for environmental air monitoring and waste management at NYC sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →