Ambient Air Monitoring Program Section No. 11 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 76 of 124

• an aspect ratio of 3:1 or greater • greater than 5 microns in length

Analysis will be performed at a magnification of approximately 2000x with higher magnifications of 10,000 and 20,000x used as needed for precise measurements and identification of individual fibers. Only PCME fibers (both asbestos and non-asbestos) are recorded. Eibers that intersect a grid bar will be recorded as /z fiber but only if the visible portion is a least 2.5 microns in length. As with the AHERA analysis, identification of asbestos will be performed by a combination of morphology, SAED, and EDXA. Enough grid openings will be analyzed during this phase of analysis to reach a project-specific target analytical sensitivity of less than 0.0009 fibers/cm\

In addition, samples may also be analyzed using Scanning Electron Microscopy (SEM) due to the potential overloading problem with TEM which may be caused by excess particulates. This will be determined on a sample-specific basis and performed as needed. SEM is a well- established methodology that utilizes a scanning electron microscope. The SEM can work in many different magnification ranges from lOOx to 20,000x. The sample preparation is different than TEM, whereas samples are gold coated and mounted on a stub, with minimal degradation to the original sample. The SEM is more flexible with regard to types of material you can introduce into the chamber. SEM can achieve much better contrast than TEM and results in almost a 3-D image whereas the TEM is a 2-D “shadow”. SEMs are typically equipped with Energy Dispersive X-Ray analyzers (EDXA) just like TEM. This enables the analyst to determine the elemental composition of a material or fiber observed. The SEM is not equipped with Electron Diffraction capabilities unlike the TEM, which allows the analyst to determine the crystal structure of a mineral based on a distinct pattern of spots that is produced from the bombardment of an electron beam. Selected Area Electron Diffraction (SAED) is cited in many TEM methods including AHERA and is required to yield a definitive asbestos identification. Eor this project, however, since the dust has been so well characterized, the need for SAED is not as essential.

1 J. J.2.4 Metals Analysis by SW-846 Method 6020A

Metals analysis will be performed using SW-846 Method 6020A with the following modifications;

• Samples will be digested using nitric acid as per 40 CER Part 50 Appendix J, not a mixture of nitric and hydrochloric acid. Sample digestion will be performed using a hotplate or Mod- block digestion procedure. • Initial ICP/MS insti-ument calibration will be performed using a blank and a single-point standard. • The routine calibration procedure will not include the analysis of a High Standard Verification (HSV) standard. Calibration will be verified with the CCB and CCV.

CITY_DEP_WORBY_CANNATA_SUBP_000058264

NYC-WTC_000423295

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423295Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000421972

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000426556

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →