Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - September 29, 2005

utilized with this sampling approach arc as follows: • Filters -8x10 inch quartz fiber filters such as Whatman QMA filters or their equivalent. • High Volume Sampler - The sampler consists of a protective housing which contains an electric, high-speed, high-volume blower; a filter holder capable of holding 8x10 inch filters; a flow controller capable for controlling the air-flow rate through the instrument at 1.0 to 1.8 m3; and a flow indicating device that works by measuring the pressure drop across the sampler such as a magnehelic gauge, a manometer, or rotameter. The sampler should have a gabled roof design. The air inlet should be uniform on all sides and be designed such that the effective particle capture velocity is 20 - 35 cm/sec. • Thermometer - A thermometer is used to indicate the temperature at the flow rate measurement orifice when temperature corrections are used. • Barometer - A barometer is used to indicate the barometric pressure at the flow rate orifice when pressure corrections are used. • Manometer - A water or oil manometer is used to calibrate the flows of the high volume samplers. • Timing/Control Device - A timing device capable of starting and stopping the sampler to obtain an elapsed run time of 24 hr ±1 hr. The accuracy of the timing device should be ±30 minutes. • Orifice Transfer Standard - The flow rate transfer standard is a calibrated orifice traceable to NIST standards that consists of either a set of restrictor plates or a variable restrictor that is used to deliver a series of discrete flow rates into the inlet of the high volume sampler so that the sampler flow indicating device on the sampler can be accurately calibrated.

JO.2.2 Mercury (Gas)

Real-time monitoring for mercury will be performed utilizing an OliioLumex RA 915+ direct read instrument. The OhioLumex RA 915+ is a factory-calibrated instrument based on a cold vapor Zeeman atomic absorption analytical process that reduces interference from molecular absorption bands and scattered spectra. A mercury electrodeless discharge lamp (EDL) is used as the radiation source. The sampling system consists of a sample pump operating at 20 L/min. and a multi-path sample cell with an effective path length of 10 meters. Equipment and supplies utilized with this sampling approach are as follows: • OhioLumex RA-915+ Mercury Analyzer - A portable, self-contained field mercury analyzer used to make real time mercury vapor determinations. • Air Intake Hose with Pre-Filter - The sampling line and first pass filter used to remove particulate from the sample gas. • Absorption and Dust Filters - Spare filters used as replacements for the internal particulate and mercury absorbing filters in the instrument.

10.2.3 Asbestos

45

CITY_DEP_WORBY_CANNATA_SUBP_0001 01696

NYC-WTC_000427944

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427944Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000423885

Quality Assurance Project Plan for environmental air monitoring and waste management at Greenwich and Thames sites; Sept 30, 2005.

Similar indexed content

NYC-WTC_000451195

QA plan for environmental air monitoring and waste management at NYC sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →