Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - September 29, 2005

laboratory. The laboratory completeness objective will be a minimum of 90 percent. This allows for the potential loss of samples impossible to analyze due to unforeseen interferences and rejected data following data validation.

9.0 NON-DIRECT MEASUREMENTS (SECONDARY DATA) Previously collected data and information will not be used to make project decisions or design the sampling program.

10.0 FIELD MONITORING REQUIREMENTS

10.1 Monitoring Process Design

Refer to Section 7.1.1 for the monitoring design of this project. This section discusses the areas being sampled, what is being tested, and how often.

10.1.1 Meteorological Data Collection

Potential sources of variability may be due to meteorological data. Data available from regional National Weather Stations (NWS) such as Newark Airport, LaGuardia and Kennedy Airports can be used to complement the localized data but it is likely NWS data may not always be representative of conditions in and around the 133-135 Greenwich Street and 21-23 Thames Street site. A meteorological station that will be deployed by EMDC as part of the 130 Liberty Street deconstruction project in the immediate vicinity of the site may be utilized w here needed to provide local meteriological data for comparison with monitoring data results..

10.2 Monitoring Methods

The following sections provide a brief description of the sampling procedures to be employed for each parameter and a summary of the required equipment. Step-by-step operating procedures are included as Attachment C.

10.2.1 Metals (TSP Filters)

Total suspended particulate (TSP) samples to be analyzed for metals will be collected employing high-volume air sampling techniques in accordance with US EPA standard reference method 40 CFR Part 50 Appendix B, Reference Method for the Determination of Suspended Particulate Matter in the Atmosphere (High-Volume Method). Samples will be collected over an estimated twenty-four hour sampling period. During this period ambient air will be collected at a flow rate of approximately 1 ms minute. Numbered, preweighed quartz fiber filters provided by the subcontracted laboratory will be placed in each sampling system prior to the start of each sampling event. The air sampler draws approximately 1200-1500 ma through the filter during each sampling event. The TSP quartz filters will be analyzed for ten (10) metals: antimony, barium, beryllium, cadmium, chromium, copper, lead, manganese, nickel, and zinc. Equipment and supplies

44

CITY_DEP_WORBY_CANNATA_SUBP_0001 01695

NYC-WTC_000427943

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427943Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000423885

Quality Assurance Project Plan for environmental air monitoring and waste management at Greenwich and Thames sites; Sept 30, 2005.

Similar indexed content

NYC-WTC_000451195

QA plan for environmental air monitoring and waste management at NYC sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →