Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

The field personnel will notify the laboratory 24 to 48 hours in advance of sample shipment so that the laboratory personnel may get prepared for the sample receipt and analysis. Samples will be packed and shipped in accordance with applicable U.S. Department of Transportation (DOT) regulations, Environmental Consultant Corporate Guidelines, and International Air Transport Association (IATA) standards (if shipped by air carrier, as detailed in the most current edition of IATA Dangerous Goods Regulations for hazardous materials shipments). Samples will be prepared and shipped to the laboratory according to the following procedures:

1. All sample jars, once cleaned and labeled, will be placed in clean plastic re- sealable bags. Medium or high concentration samples (determined through field observations, field screening, air monitoring, or all three) will also be packaged in metal cans. The lids of the metal cans will be secured with at least three metal lid clips. The exterior of the metal cans will be labeled in the same fashion as the sample jar. 2. Place samples in a cooler and surround them with vermiculite (or equivalent) packing material for moisture absorption and stability during transport. 3. Place sufficient double-bagged ice in the cooler to maintain 4°C temperature. 4. Place a "temperature blank", consisting of a water-filled plastic container, in each cooler. The temperature blank will be recorded by the laboratory upon receipt to ensure adequate sample temperature. 5. Place completed COG form inside a re-sealable plastic bag, and tape the bag to the inside of the cooler lid. 6. Secure the cooler lid with packing tape. Place signed and dated custody seals on two opposite sides of the lid and secure with clear tape. 7. If applicable, tape the drain plug closed so that it will not open. 8. Place upward-pointing arrow label on two opposing vertical sides of the cooler. 9. Label the cooler with laboratory address, name of laboratory contact, telephone number, and project identification. 10. Attach applicable IATA and/or DOT identification labels. 11. Attach a completed courier shipping label (if applicable).

Samples will be classified as environmental samples unless there is evidence of high concentrations of chemical constituents, based on visual observations, odors, previous sample data, or other criteria. All waste liquid, waste solid, tank, drum, and other container samples will be considered hazardous material samples and will be packaged and transported in conformance with the U.S. DOT, U.S. Postal Service (USPS), and the IATA Dangerous Goods Regulations if shipped by air carrier. These regulations/requirements have de minimus exemptions for small volume samples; they will be referred to prior sample shipment to ensure all requirements are being met.

The United States Environmental Protection Agency’s Environmental Response Team (EPA ERT) publishes sampling SOPs for sampling at CERCLA hazardous waste sites. These SOPs will be followed during the sampling at this site.

64

CITY_DEP_WORBY_CANNATA_SUBP_0001 01095

NYC-WTC_000427779

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427779Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

Compare copies and versions →