The field personnel will notify the laboratory 24 to 48 hours in advance of sample
shipment so that the laboratory personnel may get prepared for the sample receipt and
analysis. Samples will be packed and shipped in accordance with applicable U.S.
Department of Transportation (DOT) regulations, Environmental Consultant Corporate
Guidelines, and International Air Transport Association (IATA) standards (if shipped by
air carrier, as detailed in the most current edition of IATA Dangerous Goods Regulations
for hazardous materials shipments). Samples will be prepared and shipped to the
laboratory according to the following procedures:
1. All sample jars, once cleaned and labeled, will be placed in clean plastic re-
sealable bags. Medium or high concentration samples (determined through field
observations, field screening, air monitoring, or all three) will also be packaged in
metal cans. The lids of the metal cans will be secured with at least three metal lid
clips. The exterior of the metal cans will be labeled in the same fashion as the
sample jar.
2. Place samples in a cooler and surround them with vermiculite (or equivalent)
packing material for moisture absorption and stability during transport.
3. Place sufficient double-bagged ice in the cooler to maintain 4°C temperature.
4. Place a "temperature blank", consisting of a water-filled plastic container, in each
cooler. The temperature blank will be recorded by the laboratory upon receipt to
ensure adequate sample temperature.
5. Place completed COG form inside a re-sealable plastic bag, and tape the bag to
the inside of the cooler lid.
6. Secure the cooler lid with packing tape. Place signed and dated custody seals on
two opposite sides of the lid and secure with clear tape.
7. If applicable, tape the drain plug closed so that it will not open.
8. Place upward-pointing arrow label on two opposing vertical sides of the cooler.
9. Label the cooler with laboratory address, name of laboratory contact, telephone
number, and project identification.
10. Attach applicable IATA and/or DOT identification labels.
11. Attach a completed courier shipping label (if applicable).
Samples will be classified as environmental samples unless there is evidence of high
concentrations of chemical constituents, based on visual observations, odors, previous
sample data, or other criteria. All waste liquid, waste solid, tank, drum, and other
container samples will be considered hazardous material samples and will be packaged
and transported in conformance with the U.S. DOT, U.S. Postal Service (USPS), and the
IATA Dangerous Goods Regulations if shipped by air carrier. These
regulations/requirements have de minimus exemptions for small volume samples; they
will be referred to prior sample shipment to ensure all requirements are being met.
The United States Environmental Protection Agency’s Environmental Response Team
(EPA ERT) publishes sampling SOPs for sampling at CERCLA hazardous waste sites.
These SOPs will be followed during the sampling at this site.