QAPP AMENDMENT FORM: Issue 2

Either white cotton gloves or nitrile gloves can be used to handle the filters and/or cartridges associated with dioxin/furan, PCB, and PAH sampling.

Reason for Amendment:

The QAPP listed only the option for white cotton gloves but nitrile gloves were also deemed to be acceptable for handling the sample media and easier to work with. SOPs written subsequent to the QAPP provided an option for nitrile or white cotton gloves. Therefore, this QAPP amendment has been issued so as to be consistent with the project SOPs and also provide this option.

Sections of QAPP Affected:

Section 10.2.5, Polychlorinated Dibenzodioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs): Nitrile gloves will be included as an option to the white cotton gloves. Section 10.2.6, Polychlorinated Biphenyls (PCBs): Nitrile gloves will be included as an option to the white cotton gloves. Section 10.2.7, Polycyclic Aromatic Hydrocarbons (PAHs): Nitrile gloves will be included as an option to the white cotton gloves.

Date Implemented:

November 2005 (Phase I)

The flow rate used to collect samples for silica analysis was increased from approximately 2 to 2.5 L/minute for an estimated total volume of 3.5 m^ instead of 2.9 m^.

Reason for Amendment:

The quantitation limit for silica prior to the increase in flow rale was approximately 2 ug/iii\ which is a factor of 5 below the Target Air Quality Level of 10 ug/m^. The flow rate was increased to obtain a lower quantitation limit for silica. The new quantitation limit for quartz silica is 1 ug/nY (6 ug/iiY for the rare forms of crystalline silica [cristobalite and tridymite]) which is a factor of 10 below the Target Air Quality Level. Therefore, this reduces the potential for false positive results (e.g., quantitation limits greater than or approaching the action levels), enhances the quantitation limits for all forms of crystalline silica, and enhances the quantitation limits when secondary peak interference is present.

Sections of QAPP Affected:

QAPP Amendment #2 (10/7/05 QAPP Amendment Form): The previous QAPP Amendment will be modified with the new sample volume. Table 8-1: The estimated volume to be collected for silica will increase from 2.88 mOo 3.5 m’. The quantitation limit for silica will decrease from 2 ug/m ’ to 1 ug/m^ (with quantitation limits of 6 ug/m’ for the rare forms of crystalline silica [cristobalite and tridymite]). Section 10.2.4, Respirable Crystalline Silica and Dust: The flow rate will increase from approximately 2 to 2.5 L/minute for an estimated total volume of 3.5 m^. Table 12-1: The flow rate will increase from approximately 2 to 2.5 L/minute for an estimated total volume of 3.5 m’.

Date Implemented:

November 2005 (Phase T)

Page 4 of 7

CITY_DEP_WORBY_CANNATA_SUBP_000078985

NYC-WTC_000425344

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000425344Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427863

QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.

Similar indexed content

NYC-WTC_000446799

QAPP amendment documenting mercury spike level increase from 50 to 150 ng.

Similar indexed content

NYC-WTC_000441952

QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.

Similar indexed content

Compare copies and versions →