11.0 ELECTRONIC DATA MANAGEMENT AND REPORTING
11.1 Data Acquisition Systems
The primary data acquisition system for the continuous monitors and the meteorological system
will be the CSI CR510 data logger. The data logger has inputs for 4 single-ended analog
channels. Each data channel will be sampled once per second with an accuracy of + 0.1 percent
of full scale. Both 5-minute and hourly averages will be calculated. The data loggers are
programmable, and additional information such as maxima, minima, and frequency histograms
can be collected.
11.2 Data Management
The current Contractor Environmental Subcontractor has developed an ensemble of systems for
electronic data management of nearly all phases of environmental monitoring projects that will
be used to manage the collection and reporting of data from this project. These systems, or
equivalent, will be utilized for the management of data:
EnviroData® provides a standardized means for porting laboratory electronic data
deliverables (EDDs) into Microsoft® Access® databases;
MonitorFast®^ provides a framework for automated data retrieval from monitoring stations to
standardized SQL Server databases either periodically or in real-time;
• FieldFast enables direct electronic entiy of field sampling data from the Asbestos, PUF and
TSP samplers; and
TeamLink®^ provides a secure Web-based data access portal and project management tool.
Each of these technologies is described further in Appendix A of this document.
11.3 Reporting
Samples will be shipped overnight to the laboratory the day after the sample period. Please refer
to Table 7 for proposed laboratory turnaround times on a parameter specific basis. Data reporting
schedules and frequencies are also provided. PAHs, PCB, and D/F’s data collected are loaded to
the EnviroData database, or equivalent on Contractor Environmental Subcontractor’s server
within 48 hours of receipt of the EDD from the laboratory. The data can be viewed in tabular
format through the Teamlink®^ Website, or equivalent.
For continuous monitors and the meteorological station, the data loggers will record data at
Sminute and 60-minute intervals. The data will be downloaded from the loggers to the databases
on a minimum of once daily, and reviewed by the Contractor Environmental Subcontractor
Project Scientists. The frequency of data retrieval can be increased in MonitorFast®^ , or
equivalent to obtain access to results in near-real time.