hold the cassette securely in place and to provide a surface to identify the cassette. By
inserting a pin through the hole near the display screen, the elapsed time indicator is reset
prior to sampling. At the end of the sampling period, the top cover and small end caps are
replaced. Samples are transported upright to the laboratory in a rigid container with
packing material to prevent jostling or damage. To avoid electrostatic forces from
causing fiber loss from the sampling filter, untreated polystyrene foam will not be used
for any of the shipping container materials. Collection of a site-specific dust sample will
be performed as discussed in Section 8.2.2. This sample needs to be double-bagged prior
to shipment to avoid any potential cross-contamination. Equipment and supplies utilized
with this sampling approach are as follows:
• Personal Monitor and Sampling Pump 0.5 to 3 1pm • Battery Pack - Nickel metal
hydride battery pack (or equivalent), fitted with a belt clip, compatible with the
personal sampling pump.
• Filters - Polyvinyl filter (or equivalent hydrophobic membrane filter) supported
by a cassette filter holder, 5.0-|Jm pore size, suitable for connection with the
personal monitoring pump system.
• Cyclone - SKC Inc. aluminum cyclone (or equivalent) • Medium Flow Rotometer
- 0.4 to 4.0 1pm • High Flow Rotometer - 2.0 to 20.0 1pm • Forceps - Nylon, used
when handling the filters
10.2.5 Polychlorinated Dibenzodioxins (PCDDs) and Polychlorinated
Dibenzofurans (PCDFs)
Ambient air samples will be collected using a General Metals Works (GMW) PS-1
(or performance equivalent) high volume air sampling system equipped for the collection
of semivolatile PCDD/PCDF particulate matter on a 102-mm diameter microquartz fiber
filter, as well as a glass cylinder containing a polyurethane sorbent (i.e., PUF plug) for
the collection of gas phase PCDDs/PCDFs. At each site, one GMW PS-1 sampler will be
used to collect PCDD/PCDF samples according to Method TO-9A. Samples will be
collected at a flow rate of 200 to 300 liters per minute (Ipm) over a sampling period of
approximately 24 hours for a resulting total air volume of approximately 288-432 cubic
meters (288-432 rm). The PUF (Polyurethane Foam) sampler is a complete air sampling
system designed to simultaneously collect suspended airborne particulates as well as trap
airborne organic vapors. The PUF sampler is equipped with a bypass blower motor
arranged with an independent cooling fan. This feature permits the motor to operate at
low sampling flow rates for extended periods without motor failure from overheating. A
dual chambered aluminum sampling module contains both filtering systems. The
upper chamber supports the airborne particulate filter media in a circular filter holder.
The lower chamber encapsulates a glass cartridge, which contains the PUF for vapor
entrapment. The voltage variator adjustment screw alters the blower motor speed to
achieve the desired flow rate. Air flow rate is measured through the flow venturi utilizing
a 0-100” Magnehelic Gage. For each sample, the sampling start and end times and flow
rates are recorded on Field Sampling Data Sheets or an equivalent field logbook and used
to calculate the amount of ambient air sampled. At the conclusion of each sampling
57