Station Location relative to wind Asbestos-AHERA result (s/mm“) Silica result (ug/m’)
Station 6 Upwind ____________ <19____________ 5
Station 7 Upwind ____________ <19____________ 10.1
Station 8 _______ Upwind_______ _____________ 96_____________ _______ <2
Station 9 Downwind 19 <2
Corrective Action:
As a result of the roof abatement completion, samples were not collected on September 29, 2005
at air monitoring Stations 6, 7, 8, or 9. However, per ICR 56, the roof area was re-cleaned
utilizing additional supplemental wet-methods and Asbestos-AHERA air monitoring reinstated
on the roof for September 30, 2005 in order to confirm that concentrations were below the
USEPA Site-Specific Trigger Level for Asbestos. Five samples were collected, one on each roof
corner and one in the roof center and analyzed for TEM EPA 40 CFR Pail 763. No asbestos was
detected in the five samples (< 15 s/mm’). These results are attached in the Supporting Data.
Going forward, TRC will continue to closely monitor the use of dust control practices including
frequently wetting surfaces containing dust with amended water during the work.
Supporting Data attached:
1. Analytical Data summary -Asbestos-AHERA and Silica analytical results for all stations
on the date of the exceedance and the additional Asbestos-AHERA sampling which
occuiTed on September 30, 2005.
2. Particulate Data -
Plot of PM2.5 and PMw concentrations (1 O-minute averages) versus time for the station where the
exceedance occurred.
3. Meteorological Data - wind rose plots for the sample collection period of interest
4. Visual Inspection Reports - visible dust emission monitoring summaries from the 130
Liberty Street project.
5. Photographs of activities at and near the station where the exceedance occurred
Submitted By: Ed Gerdts Date: October 6, 2005
CITY_DEP_WORBY_CANNATA_SUBP_000071672
NYC-WTC_000424078