AHERA exceedance report, 130 Liberty Street, Sep 2005

Machine-extracted title · confidence 43%

Exceedance summary for asbestos AHERA on roof air samples, 130 Liberty Street, Sep 2005.

NYC-WTC_000424077–000424078
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TRC Customer-Focused Solutions

Lower Manhattan Development Corporation 130 Liberty Street Deconstruction Project Exceedance Report October 6,2005 Date of Exceedance: Wednesday, September 28,2005

Analyte Asbestos AHERA Silica-Quartz Location Station 8, northeast area, Station 7, roof level __________________ Concentration 96 s/mm^ 10.1 ug/m^ USEPA Site-Specific Trigger Level 70 s/mm^ 10 iig/nT Target Air Quality Level: N/A 10 iig/nT

Summary of Event:

An exceedance of the USEPA Site-Specific Trigger Level of Asbestos AHERA and Silica Quartz occurred on the roof level at 130 Liberty Street (Building) for air samples collected on September 28, 2005. The samples were sent to and received by EMSL Analytical Inc. laboratory (NYSDOH ELAP #10872) on September 29, 2005. On September 30, 2005, the Asbestos AHERA sample was analyzed for TEM EPA 40 CER Part 763 and the results reported. On October 4, 2005, the Silica-Quartz sample was analyzed for NIOSH 7500 XRD and the results reported. The laboratory reports are included in the attached Supporting Data.

Activities at 130 Liberty Street on this date included completion of the roof abatement. Work occurred from 8:00 AM through 5:00 PM. The work included gravel removal, vacuuming and wet-wiping all roof surfaces including, but not limited to, vents, mechanical surfaces, bulk heads, roof floor, and parapet wall. Cleaning and abating the masonry parapet wall could potentially have impacted the Silica sample, contributing to the Silica exceedance, since sand is a component of the brick mortar and was obserx ed on the parapet wall.

According to the Visual Inspection Report, attached in the Supporting Data, no visual emissions were observed in the roof vicinity. Photographs taken on September 28, 2005 of roof activities were taken and are also included in the Supporting Data.

The wind rose, included in the attached Supporting Data, from the meteorological station located on the roof indicates a predominant south-south-east wind direction. The Asbestos-AHERA and Silica results of stations located on the roof and their locations respective to the wind direction are summarized below.

Submitted By: Ed Gerdts Date: October 6, 2005

CITY_DEP_WORBY_CANNATA_SUBP_000071671

NYC-WTC_000424077

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000424077Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →