NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
PMio and PM2.5 Using a Reference Sampler
Calibration procedures are as follows:
• Transfer Standard Calibration Frequency - The flow rate transfer standard should
be sent back to the manufacturer annually for recalibration. Also, if any visual
inspection reveals new defects in the device, then it should be sent back to the
manufacturer for recalibration. The calibration records will be maintained and
tracked by the Quality Assurance Officer and Field Sampling Coordinator.
• Calibration of the Samplers - A multipoint flow-rate calibration consisting of at
least three (3) points must be performed before first use and quarterly thereafter.
Additionally, the sampler should be calibrated after any repairs that might affect
calibration; after relocation of the sampler to a different site; or if the results of a
field QC flow check exceed ±10% of the samplers indicated flow rate.
PMio and PM2.5 Using a Met One E-BAM Continuous Monitor Calibration
verification is performed using two calibration plates that represent a Zero and
Span factory set calibration points. Check that the serial number on calibration plates
matches the serial number of the E-BAM to be calibrated. If Zero or Span tests fail, re
run the test. If failure continues, clean the detector and re-run the test. If failure persists,
contact the manufacturer.
13.2.2 Analytical Laboratory Equipment
Table 13-4 details the calibration procedures associated with all fixed laboratory
instruments. These calibration procedures ensure that the analytical methods and selected
instrumentation meet project requirements for selectivity, sensitivity, accuracy and
precision of quantitation. These calibration procedures are also discussed in the
individual methods.
13.3 Inspection/Acceptance of Supplies and Consumables
13.3.1 Field Supplies/Consumables Critical supplies and sample containers will be
inspected in the following manner.
Cnde%i Supplies aiul ReqEiit'etRfitG
CoBsioBsitles sad AcsepsaMe Criteria
Ss3S@53e Isaaies, us-hs VasusHy Epoa isceapi fii i:rs£3:s, biiealssgs,
sifesodiEsss. fee acCTaipaassa fev cEstificaSe ci aastvsis,
OissasE its isiiit E^agsisB YisnaHy sse bbelsa®, es^sEa&as dsSes,
sppirejjasM aide
Record tet isiaaser? reag=a.B ased for icaWstioa.,