QAPP Title Quality Assurance Project Plan for the Ambient Air Monitoring Program 130 Liberty Street Deconstruction Project September 7,2005
Concentration of mercury field spike was increased from 50 ng to 150 ng. Reason for Amendment: Accurate recoveries were not always achievable at the lower spike level of 50 ng due to background levels (< 15 ng) of mercury present in the media. Increasing the spiking level to 150 ng will cause the background levels of mercury to be negligible when calculating recoveries of field spikes. This new spiking level results in a mercury concentration of approximately 250 ng/nf’ with the volumes of 0.6 m^ currently being sampled. This concentration is just below the Target Air Quality level of 300 ng/m’ and will therefore provide more useful accuracy data at the project action level. Sections of QAPP Affected: 8.2.1, Field Precision Objectives: Change 50 ng/trap to 150 ng/trap beginning with samples from Phase I 8.2.2, Field Accuracy Objectives: Change 50 ng/trap to 150 ng/trap beginning with samples from Phase I 10.3.4, Field Spikes, Total Mercury: Change 50 ng/trap to 150 ng/trap beginning with samples from Phase I Date Implemented: September 2005 (Phase I)___________________________________________________________________
Samples for respirable silica will be collected for 24 hours instead of eight hours. Sample volumes will therefore increase from approximately 1.0 m^ to 2.88 m^. Reason for Amendment: The sample collection time for respirable silica was increased from eight to 24 hours due to the need to accommodate two work shifts. Based on discussions with the analytical laboratory (EMSL Analytical), the increased sample volume will not cause problems for the respirable silica analysis. The only potential problem (which will be monitored by IRC) is if the filter becomes overloaded with particulate causing resistance which may affect the pump flow rates. Pre and post calibrations performed by TRC will monitor for this potential scenario. If this problem occurs, sampling times will be reduced and replaced with an additional subsequent sample to ensure proper monitoring of silica during the two work shifts. Sections of QAPP Affected: 6.3.3.1, Definition of Exceedances: The reference to an eight-hour value for silica should be removed. Tables 7-2 and 7-3: Silica should be deleted from the list of analyses collected each work shift and added to the list of analyses collected on a 24-hour basis. Table 8-1: The estimated volume to be collected for silica will increase from 1.0 n? to 2.88 n?. The quantitation limit for silica will decrease from 5 ug/m ’ to 2 ug/m’ (with quantitation limits of 7 ug/m’ for the rare forms of crystalline silica [cristobalite and tridymite]). Section 10.2.4, Respirable Crystalline Silica and Dust: The time of collection will be changed from eight hours to 24 hours for a resulting total air volume of approximately 2,88 m\ Table 12-1: The estimated sample volume will change from 1,0 m’ (2.0 - 2.1 L/min. for 8 hours) to 2.88 m’ (2.0 - 2.1 L/min. for 24 hours). Date Implemented: September 21,2005 (Phase I)
Page 1 of 3
CITY_DEP_WORBY_CANNATA_SUBP_000059047
NYC-WTC_000423693
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000451189
QAPP amendment updating mercury spike level from 50 ng to 150 ng.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427863
QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.
7 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425322
QAPP amendment modifying mercury spike level to 150 ng for field samples, Oct 2005.
7 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446799
QAPP amendment documenting mercury spike level increase from 50 to 150 ng.
7 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441952
QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.
7 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425341
QAPP amendment detailing calibration and flow-rate procedures for metals samplers; dated 4/5/06.
7 shared non-person entities · similarity 0.919
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451394
QAPP amendment detailing flow rate and calibration changes for high-volume samplers, submitted 2006.
7 shared non-person entities · similarity 0.918
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
4 shared non-person entities · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162838
Correspondence regarding Schedule A forms and a draft scope of work for cleaning and air monitoring contracts at the site.
4 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
4 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
4 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
4 shared non-person entities · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
QAPP amendment updating mercury spike level from 50 ng to 150 ng.
Similar indexed content
QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.
Similar indexed content
NYC-WTC_000425322
QAPP amendment modifying mercury spike level to 150 ng for field samples, Oct 2005.
Similar indexed content
QAPP amendment documenting mercury spike level increase from 50 to 150 ng.
Similar indexed content
QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.
Similar indexed content