QAPP AMENDMENT FORM DATE FORM SUBMITTED: 10/7/05

QAPP Title Quality Assurance Project Plan for the Ambient Air Monitoring Program 130 Liberty Street Deconstruction Project September 7,2005

Concentration of mercury field spike was increased from 50 ng to 150 ng. Reason for Amendment: Accurate recoveries were not always achievable at the lower spike level of 50 ng due to background levels (< 15 ng) of mercury present in the media. Increasing the spiking level to 150 ng will cause the background levels of mercury to be negligible when calculating recoveries of field spikes. This new spiking level results in a mercury concentration of approximately 250 ng/nf’ with the volumes of 0.6 m^ currently being sampled. This concentration is just below the Target Air Quality level of 300 ng/m’ and will therefore provide more useful accuracy data at the project action level. Sections of QAPP Affected: 8.2.1, Field Precision Objectives: Change 50 ng/trap to 150 ng/trap beginning with samples from Phase I 8.2.2, Field Accuracy Objectives: Change 50 ng/trap to 150 ng/trap beginning with samples from Phase I 10.3.4, Field Spikes, Total Mercury: Change 50 ng/trap to 150 ng/trap beginning with samples from Phase I Date Implemented: September 2005 (Phase I)___________________________________________________________________

Samples for respirable silica will be collected for 24 hours instead of eight hours. Sample volumes will therefore increase from approximately 1.0 m^ to 2.88 m^. Reason for Amendment: The sample collection time for respirable silica was increased from eight to 24 hours due to the need to accommodate two work shifts. Based on discussions with the analytical laboratory (EMSL Analytical), the increased sample volume will not cause problems for the respirable silica analysis. The only potential problem (which will be monitored by IRC) is if the filter becomes overloaded with particulate causing resistance which may affect the pump flow rates. Pre and post calibrations performed by TRC will monitor for this potential scenario. If this problem occurs, sampling times will be reduced and replaced with an additional subsequent sample to ensure proper monitoring of silica during the two work shifts. Sections of QAPP Affected: 6.3.3.1, Definition of Exceedances: The reference to an eight-hour value for silica should be removed. Tables 7-2 and 7-3: Silica should be deleted from the list of analyses collected each work shift and added to the list of analyses collected on a 24-hour basis. Table 8-1: The estimated volume to be collected for silica will increase from 1.0 n? to 2.88 n?. The quantitation limit for silica will decrease from 5 ug/m ’ to 2 ug/m’ (with quantitation limits of 7 ug/m’ for the rare forms of crystalline silica [cristobalite and tridymite]). Section 10.2.4, Respirable Crystalline Silica and Dust: The time of collection will be changed from eight hours to 24 hours for a resulting total air volume of approximately 2,88 m\ Table 12-1: The estimated sample volume will change from 1,0 m’ (2.0 - 2.1 L/min. for 8 hours) to 2.88 m’ (2.0 - 2.1 L/min. for 24 hours). Date Implemented: September 21,2005 (Phase I)

Page 1 of 3

CITY_DEP_WORBY_CANNATA_SUBP_000059047

NYC-WTC_000423693

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423693Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451189

QAPP amendment updating mercury spike level from 50 ng to 150 ng.

Similar indexed content

NYC-WTC_000427863

QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.

Similar indexed content

NYC-WTC_000446799

QAPP amendment documenting mercury spike level increase from 50 to 150 ng.

Similar indexed content

NYC-WTC_000441952

QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.

Similar indexed content

Compare copies and versions →