NYC 9/11 Public Portal Document
Cusfomerhocused SolufIons
1430 Broadway, 10th Fl. New York, New York 10018
Phone: (212) 221-7822 - Fax: (212) 221-7840
LMDC Air Metals Profile
Client Lower Manhattan Development Corporation Job Number 46600-0000-00001
Address One Liberty Plaza, 20th Floor Date Received 6/5/2005
New York, NY 10006 Date Analyzed 6/5/2005
Collected By O. Kuepper/K. DaRocha Job Location 130 Liberty Street
Collected 6/4/2005
Rotometer Standard
Lab ID 010502075-0001 Matrix Air
Field ID M-060405-787
Location Washington Street/Albany Street
Parameter Start End Flow Volume Result Units MDL MCL Flag
Barium, Total 18:02 16:02 4 5280 <0.95 Hg/m3 0.9500 500
Beryllium, Total 18:02 16:02 4 5280 <0.038 Hg/m3 0.038 1
Cadmium, Total 18:02 16:02 4 5280 <0.038 Hg/m3 0.038 2.5
Chromium, Total 18:02 16:02 4 5280 <0.095 Hg/m3 0.095 500
Copper, Total 18:02 16:02 4 5280 <0.19 Hg/m3 0.19 500
Lead, Total 18:02 16:02 4 5280 <0.095 Hg/m3 0.095 30
Manganese, Total 18:02 16:02 4 5280 <0.14 |jg/m3 0.14 1000
Nickel, Total 18:02 16:02 4 5280 <0.19 Hg/m3 0.19 500
Zinc, Total 18:02 16:02 4 5280 <0.19 Hg/m3 0.19 2500
Lab ID 010502075-0002 Matrix Air
Field ID M-060405-788
Location Albany Street/Greenwich Street
Parameter Start End Flow Volume Result Units MDL MCL Flag
Barium, Total 18:05 16:07 4 5288 <0.95 Hg/m3 0.9500 500
Beryllium, Total 18:05 16:07 4 5288 <0.038 Hg/m3 0.038 1
Cadmium, Total 18:05 16:07 4 5288 <0.038 Hg/m3 0.038 2.5
Chromium, Total 18:05 16:07 4 5288 <0.095 Hg/m3 0.095 500
Copper, Total 18:05 16:07 4 5288 <0.19 Hg/m3 0.19 500
Lead, Total 18:05 16:07 4 5288 <0.095 Hg/m3 0.095 30
Manganese, Total 18:05 16:07 4 5288 <0.14 Hg/m3 0.14 1000
Nickel, Total 18:05 16:07 4 5288 <0.19 Hg/m3 0.19 500
Zinc, Total 18:05 16:07 4 5288 <0.19 Hg/m3 0.19 2500
MDL = Minimum Detection Limit
MCL = Maximum Contaminant Level
> MCL = Exceeds Maximum Contaminant Level
Samples analyzed by EMSL Analytical, Inc.; NY ELAP ID# 10872 and 11506 Page 1 of 3
CITY_DEP_WORBY_CANNATA_SUBP_000057256
NYC-WTC_000422940
OCR can misread numbers and units. Confirm readings against the page image before using them.