LMDC Air Metals Profile
Client Lower Manhattan Development Corporation Job Number 46600-0000-00001
Address One Liberty Plaza, 20th Floor Date Received 6/5/2005
New York, NY 10006 Date Analyzed 6/5/2005
Collected By O. Kuepper/K. DaRocha Job Location 130 Liberty Street
Collected 6/4/2005
Rotometer Standard
Lab ID 010502075-0003 Matrix Air
Field ID M-060405-789
Location Greenwich Street
Parameter Start End Flow Volume Result Units MDL MCL Flag
Barium, Total 18:08 16:11 4 5292 <0.94 Hg/m3 0.9400 500
Beryllium, Total 18:08 16:11 4 5292 <0.038 Hg/m3 0.038 1
Cadmium, Total 18:08 16:11 4 5292 <0.038 Hg/m3 0.038 2.5
Chromium, Total 18:08 16:11 4 5292 <0.094 Hg/m3 0.094 500
Copper, Total 18:08 16:11 4 5292 <0.19 Hg/m3 0.19 500
Lead, Total 18:08 16:11 4 5292 <0.094 Hg/m3 0.094 30
Manganese, Total 18:08 16:11 4 5292 <0.14 |jg/m3 0.14 1000
Nickel, Total 18:08 16:11 4 5292 <0.19 Hg/m3 0.19 500
Zinc, Total 18:08 16:11 4 5292 <0.19 Hg/m3 0.19 2500
Lab ID 010502075-0004 Matrix Air
Field ID M-060405-790
Location Greenwich Street/Liberty Street
Parameter Start End Flow Volume Result Units MDL MCL Flag
Barium, Total 18:11 16:15 3.9 5164 <0.97 Hg/m3 0.9700 500
Beryllium, Total 18:11 16:15 3.9 5164 <0.039 Hg/m3 0.039 1
Cadmium, Total 18:11 16:15 3.9 5164 <0.039 Hg/m3 0.039 2.5
Chromium, Total 18:11 16:15 3.9 5164 <0.097 Hg/m3 0.097 500
Copper, Total 18:11 16:15 3.9 5164 <0.19 Hg/m3 0.19 500
Lead, Total 18:11 16:15 3.9 5164 <0.097 Hg/m3 0.097 30
Manganese, Total 18:11 16:15 3.9 5164 <0.15 Hg/m3 0.15 1000
Nickel, Total 18:11 16:15 3.9 5164 <0.19 Hg/m3 0.19 500
Zinc, Total 18:11 16:15 3.9 5164 <0.19 Hg/m3 0.19 2500
MDL = Minimum Detection Limit
MCL = Maximum Contaminant Level
> MCL = Exceeds Maximum Contaminant Level
Samples analyzed by EMSL Analytical, Inc.; NY ELAP ID# 10872 and 11506 Page 2 of 3