NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 132 pages

Quality Assurance Plan for Ambient Air Monitoring, 130 Liberty Street

Machine-extracted title · confidence 60%

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

NYC-WTC_000421972–000422103
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 2 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 4 of 124

8.2.6 Completeness 57 9.0 NON-DIRECT MEASUREMENTS (SECONDARY DATA) 58 10.0 FIELD MONITORING REQUIREMENTS............................ 59 10.1 Monitoring Process Design........................................................ 59 10.1.1 Meteorological Data Collection 59 10.2 Monitoring Methods......................... 59 10.2.1 Metals (TSP Filters)...................................................................... 59 10.2.2 Mercury (Gas)............................................................................... 60 10.2.3 Asbestos........................................................................................ 61 10.2.4 Respirable Crystalline Silica and Dust........................................ 62 10.2.5 Polychlorinated Dibenzodioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs)............................................................... 63 10.2.6 Polychlorinated Biphenyls (PCBs).............................................. 65 10.2.7 Polycyclic Aromatic Hydrocarbons (PAHs)............................... 66 10.2.8 Mercury (Total)............................................................................. 68 10.2.9 PM 10................................................................................................................................................... 69 10.2.9.1 PMio - Reference Method via Anderson RAAS samplers 69 10.2.9.2 PMio- Continuous Monitoring of PMio via Met One E-BAM Samplers.... 70 10.2.10 PM2.5...... 70 10.2.10.1 PM25- Reference Method via Anderson RAAS Samplers 70 10.2.10.2 Continuous Monitoring of PM2.5 via Met One E-BAM Samplers 71 10.3 Field Quality Control 72 10.3.1 Field Blanks/Trip Blanks.... 72 10.3.2 Cooler Temperature Blanks 72 10.3.3 Field Duplicates.................. 72 10.3.4 Field Spikes......................... 72 10.3.5 Breakthrough Checks......... 73 10.3.6 Media Certification Checks 73 11.0 ANALYTICAL REQUIREMENTS 74 11.1 Analytical Methods......................... 74 11.1.1 Fixed Laboratory Analytical Methods and SOPs............ 74 11.1.2 Fixed Laboratory Analytical Method/SOP Modifications 74 11.1.2.1 PAH Extraction by EPA Method TO-13A and Analysis by SW-846 Method 8270C...................................................................................... 74 11.1.2.2 Dioxin Extraction by EPA Method TO-9A........................................ 74 11.1.2.3 Asbestos Analyses by TEM (AHERA)................................................ 75 11.1.2.4 Metals Analysis by SW-846 Method 6020A...................................... 76 11.1.2.5 PCB Analysis........................................................................................ 77 11.2 Analytical Quality Control.............................. 77 11.2.1 Field Analytical QC................................ 77 11.2.2 Fixed Laboratory QC.............................. 77 11.2.2.1 Method Blanks/Preparation Blanks 77 11.2.2.2 Instrument Blanks........................... 78

CITY_DEP_WORBY_CANNATA_SUBP_000052371

NYC-WTC_000421976

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000421976Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000423219

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

Similar indexed content

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000426556

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →