NYC-WTC_000417347
Letter enclosing emergency cleanup reports for Barclay Street site; NOV 2001 reference.
23 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Chain of custody document related to emergency cleanup activities at 125 Barclay Street, Nov 2001.
NYC-WTC_000420989–000421029OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document -irt r Sit.'iTzs K 2±H£1 •:;
Re: Environmental Testing Page 2 of 5
125 Barclay Street is currently being used to house various members of the rescue and recoveiy operation. There is also concern that these personnel are canying asbestos and lead contamination on their clothing when they return to the building.
H, A. Bader Consultants scope of work was to determine if there is a potential asbestos E^d/or lead related health concern in the building. The primary pathway for asbestos and lead to enter the building is through the ventilation systems, the main building entrances and operable windows. There are approxima^ly 50 air handling units (AHU) that have outdoor air capabilities.
H, A, Bader Consultants performed asbestos testing in or near the outdoor air intake of:evbiy AHU, Asbestos and lead testing was performed at or near every building entrance, including those used by the rescue and recovery personnel. With the exception of the Penthouse and Basement levels, asbestos, and lead surface samples were taken on the north and south sides of each floor of the building, A i^ngle asbestos, air . sample was taken in the center of the building on floors I through 10,
Once asbestos fibers enter a building they may remain airborne or settle onto fixed surfaces (primarily horizontal surfaces). Lead dust is heavy and settles very quickly, H, A, Bader Consultants testing methods concentrated on both airborne and surface testing for asbestos and only surface testing for lead.
LeadJTestmg
The U.S. Federal Department of Housing and Urban Development (HUD) and the City of New York Department of Environmental Protection (DEP) have established allowable levels of lead dust in residential settings occupied by children. The HUD/DEP clearance level is of 50 pg/R^. These levels are extremely conservative and apply to buildings where small children (less than six years old) reside or frequently visit.
21 lead dust samples were taken, 19 samples were below the level of detection (i.e,, no lead found). Two samples had detectable lead levels (41 and 69 [Xg/ft'), with only one sample exceeding the HUD/DEP guideline level. Reference the attached laboratory results from EMSL Analytical.
05726
CITY_DEP_WORBY_CANNATA_SUBP_000025865
NYC-WTC_000421019
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000417347
Letter enclosing emergency cleanup reports for Barclay Street site; NOV 2001 reference.
23 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418420
Memo discussing ongoing cleaning and air testing for OCR building, indoor/outdoor air quality results, HEPA filtration details.
11 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418094
Air sampling results for 130 [name] with DEP correspondence details.
12 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000416688
Chain-of-custody with TEM asbestos analysis details for project with ATC and EMSL.
9 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000417409
Environmental samples from rooftops; asbestos readings reported (1.8–2.5%).
6 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119373
Correspondence regarding emergency cleanup at 125 Barclay Street dated November 21, 2001.
22 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106173
Letter enclosing an asbestos testing report from October 2001 for 115-17 Chambers Street, stating no asbestos problem was found.
17 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106183
Facsimile cover sheet from District Council 37 transmitting documents to the DEP regarding environmental matters.
18 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155920
Header page of a chain of custody document from the DEP Bureau of Air, Noise, and related services.
10 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104679
Report detailing dust sampling from hospital entrances to determine asbestos content following the September 11 attacks.
7 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155951
Header page of a chain of custody document from the DEP Bureau of Air, Noise, and related services.
10 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115957
Invoice from a contractor for cleaning 3473 square feet of facade at the specified site.
4 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000417347
Letter enclosing emergency cleanup reports for Barclay Street site; NOV 2001 reference.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119373
Correspondence regarding emergency cleanup at 125 Barclay Street dated November 21, 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220372
Letter reporting follow-up asbestos and lead testing performed at various areas of 199 Chambers Street on December 5, 2001.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390162
Follow-up asbestos and lead testing at BMCC, Nov 8, 2001, with references to prior surveys.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000417347
Letter enclosing emergency cleanup reports for Barclay Street site; NOV 2001 reference.
Similar indexed content
NYC-WTC_000119373
Correspondence regarding emergency cleanup at 125 Barclay Street dated November 21, 2001.
Similar indexed content
NYC-WTC_000106173
Letter enclosing an asbestos testing report from October 2001 for 115-17 Chambers Street, stating no asbestos problem was found.
Similar indexed content
NYC-WTC_000418420
Memo discussing ongoing cleaning and air testing for OCR building, indoor/outdoor air quality results, HEPA filtration details.
Similar indexed content
Facsimile cover sheet from District Council 37 transmitting documents to the DEP regarding environmental matters.
Similar indexed content