Environmental Community Air Monitoring Program plan, Greenwich/Thames

Machine-extracted title · confidence 52%

Plan for environmental air monitoring around The Greenwich Street and Thames Street sites.

NYC-WTC_000420513–000420646
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Strcct/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

and 21-23 Thames Street. Sampling methods, sampling QC, sample handling and custody are discussed in other sections of this QAPP. Tables 7-la, 7-lb, and 7-lc provide a general summary of target parameters, and numbers of field samples and QC samples expected to be collected on a weekly basis for each phase of the program. Tables 7-2 and 7-3 provide a summary of sampling frequencies after the background phase has been completed. Sampling locations are noted on Figures 7-1 and 7-2. Photographs of each site are included in Attachment A.

Background The background ambient air sampling period will consist of one week (7 consecutive calendar days) of monitoring performed immediately prior to the start of Abatement Phase. Samples will be collected at three (3) stations. The locations include the roof of the school auditorium on Cedar Street, across Thames Street at the southeast corner of Thames and Greenwich Streets, and on the top of the sidewalk bridge on Thames Street south of the site. This third monitoring location will be located on the sidewalk bridge through the Abatement Phase and for only a portion of the Demolition Phase. Once the demolition of the 21-23 Thames Street reaches the third level (i.e., parallel to the street bridge), the monitoring station located on top of the sidewalk bridge will need to be brought down to street level in the fenced area of the school property on the south side of Thames Street east of 21-23 Thames Street. All target parameters will be collected over a 24-hour integrated period with the exception of asbestos, silica, PMio, PM2.5, and mercury. Mercury will be monitored utilizing a direct read mercury analyzer. PMio and PM2.5 will be monitored continuously at each of the three (3) sites while asbestos and silica measurements will be taken at a frequency of once per work shift at each of the sites.

Abatement Phase: During the Abatement Phase air monitoring will take place at three (3) stations each day. Background organics data from 130 Liberty Street will be used for this project. Sampling for semivolatile organics will be conducted at a once per week frequency employing the entire station network. One day per week on a rotating basis (week #1 Monday, week #2 Tuesday, etc.) samples will be collected at every station in the network. The schedule will be repeated until project completion. The semivolatile organic samples collected employing this weekly sampling frequency will not be processed for analyses; rather they will be placed in archival storage at the laboratory. A single set of samples will be selected from each weekly sampling event to undergo analyses for PCDDs/PCDs, PAHs and PCBs. The station with the highest 24-hour average PMlo concentration (pg/ma) recorded with a collocated organic sample each week will be selected for semivolatile organic analyses.

27

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000010774

NYC-WTC_000420539

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420539Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451808

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

Similar indexed content

NYC-WTC_000427582

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →