Part V - Quality Assurance Project Plan 133-135 Greenwich Strccl/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

1/10 ± 10 ng Qualify Precision samples data gross weighing ” Will be collected at a frequency of 1/day; during Abatement and Demolition Phases only 1 field/trip blank per week will be analyzed.

TABLE 8.10 Measurement Performance Criteria Waste Sample Analysis - VOC, SVOC, Pesticides/Herbicides/PCB, Metals/ Mercury, pH Instrument Activity Frequency Acceptance Corrective SOP Criteria Action Ref.* Rctunc GCMSVOC011700 BEB Tuning Every 12 Method 8260B Criteria GC/MS hours As Recalibrate system Revision 1.7 Initial cal. (5 CCC RSDs < 30%’ Rf for Volatiles stds) Method needed SPCCs >0.05, RSD Avg < Reiun blank, rerun blank Every 12 15% affected samples hours Acetone, MeCL < 25 ppb Rerun cal chk and Cont. calibration Every 12 CCCs < 25%D; SPCCs > all affected samples hours 0.05 Reiun affteced Surrogate stds. All Within Laboratory Control samples Laboratory Control Once/20 limits Rerun LCS and all samples affected samples MS/MSD Once/20 -50% to +100% of 12 hr Reiun MS/MSD and Internal samples Cal. affected samples Standards ALL Rerun affected samples Recalibrate System GCPEST011799 Initial cal. (5 As needed RSDs all <20% GC Pesticides/ stds) Cont. Rerun all affected Revision 1.1 Every 10 < 15 % Difference Herbicides and calibration samples under good GCHERB011999 samples PCBs (midpoint) Not detected cev one per Revision 1.2 method blank Within Lab control limits Reextract, rerun batch GCPCB011799 surrogate stds. Witliin lab control limits Re extract samples All Revision 1.2 MS/MSD & with both surrogates Once per out LCS 20 samples Reextract or reanalyze affected samples where LCS is out.

51

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013 CITY_DEP_WORBY_CANNATA_SUBP_000010798

NYC-WTC_000420563

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420563Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451808

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

Similar indexed content

NYC-WTC_000427582

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →