NYC-WTC_000266929
Monitoring plan listing asbestos and other dust-related controls per area.
8 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗Monitoring plan table listing lead, asbestos, and other controls for site activities.
NYC-WTC_000419329OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document 08/27/2002 16:24 FAX 2126954956 MTA ESA @1008
ATTACHMENT 1 TABLE 1 - MONiTORfNS PLAN Compound ______ Task Frequency Sample Type Per Area Lead_______ Torch cutting 1 per shift Full shift-TWA Each(4) Metals Torch cutting 1 per shift Full shift-TWA Each (4) (a) torch cutting Asbestos 1 per shift 8 hour TWA Each (4) (b) rubble removal Crystalline 8 hour TWA Rubble removal 1 per shift Each (4) silica______ (respirable) Aromatic Rubble removal 2 per week 8 hour Each (4) hydrocarbon (a) Operator Diesel exhaust 1 per week 8 hour Each (4) (b) truck drivers (a)Peak Carbon (a) torch cutting 1 per shift (b) Range Each (4) Monoxide (b) truck drivers (c) Avg._______ Compound PAHs Rubble removal 2 per week Each (4) identification Formaldehyde Rubble removal 1 per week 8 hour_____ _ Each(4) Asbestos Break area 2 per week 8 hour________ 2 per week Ozone______ Torch cutting 1 per week 8 hour________ Each (4) Crystalline 8 hour; total and Break area 2 per week 1 per week Silica respirable
TABLE 2 - WTC SAMPLE ANALYSIS METHOD Compound/Analysis Media _______ Test Method Metals_____________ Filter NIOSH 7300___________ Lead______________ _ Filter NIOSH 7082 Dust Gravimetric _________ Filter Weigh using match weight ■ Silica Crystalline - Respirable Filter & Cyclone OSHA142 Fraction, % Quartz________ _ ^.(2iT^^tic Hydrocarbons Sorbent ______ NIOSH 1501 Diesel Exhaust____________ Filter/EGA/TOV NIOSH 5040 Carbon Monoxide__________ Direct Read/Data Log PAHs_______ NIOSH 5506______________ Aldehydes________ _ Coated Sorbent NIOSH 2016______________ Ozone Filters/IC OSHA 214________________ NIOSH 7400 plus TEM and B Asbestos/Fibers Filter count fibers Optional Analyses Performed on an as needed Basis Acid Gas (HCI, HF) TBD _________________ Phosgene____________ TBD _________________ Sulfuric Acid__________ TBD_____________________ Hydrogen Sulfide______ TBD_____________________ Noise (direct read) Sound level meter/Dosimeter Dust Levels (direct read) Direct read _____________ Rad Survey (direct read) R meter/GM
05,001101
CrTY_21MC100_013430895
NYC-WTC_00041 9329
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000266929
Monitoring plan listing asbestos and other dust-related controls per area.
8 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000429605
Table outlining monitoring requirements for asbestos-related tasks and related shifts.
8 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000291425
Attachment: monitoring plan table with asbestos and crystalline silica per shift.
8 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357694
Quartz and particulates results from WTC debris operations with OEL comparisons.
4 shared non-person entities · 1 shared topics · similarity 0.872
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280608
ATC air sampling results for April 26–May 10, 2002 at WTC, including silica/particulates.
4 shared non-person entities · 1 shared topics · similarity 0.872
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209172
Document outlining NIOSH monitoring requirements for lead, asbestos, silica, and other contaminants during WTC torch cutting and rubble removal.
5 shared non-person entities · 1 shared topics · similarity 0.922
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302240
OSHA sampling results: asbestos in financial district and rubble pile; results below/exceeding limits.
4 shared non-person entities · similarity 0.879
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162838
Correspondence regarding Schedule A forms and a draft scope of work for cleaning and air monitoring contracts at the site.
5 shared non-person entities · similarity 0.873
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
7 shared non-person entities · similarity 0.873
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348353
FDNY asbestos and dust TWA sampling at WTC site, Oct 2001.
6 shared non-person entities · similarity 0.871
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000417614
FDNY asbestos air samples with TEM/AHERA results from mid-section and surrounding sites.
6 shared non-person entities · similarity 0.871
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418701
Asbestos sampling results by FDNY at mid-section towers and surrounding areas in Oct 2001.
6 shared non-person entities · similarity 0.871
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000266929
Monitoring plan listing asbestos and other dust-related controls per area.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000429605
Table outlining monitoring requirements for asbestos-related tasks and related shifts.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000291425
Attachment: monitoring plan table with asbestos and crystalline silica per shift.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280647
Doc header for health monitoring and sampling RFP, 10/01/01, contract file.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317719
SOW describing general site exposure monitoring for WTC demolition/repair work.
Similarity score 0.965 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280660
Additional pages for the WTC health monitoring and sampling RFP, city file reference.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000266929
Monitoring plan listing asbestos and other dust-related controls per area.
Similar indexed content
NYC-WTC_000429605
Table outlining monitoring requirements for asbestos-related tasks and related shifts.
Similar indexed content
NYC-WTC_000291425
Attachment: monitoring plan table with asbestos and crystalline silica per shift.
Similar indexed content
NYC-WTC_000209172
Document outlining NIOSH monitoring requirements for lead, asbestos, silica, and other contaminants during WTC torch cutting and rubble removal.
Similar indexed content
NYC-WTC_000302240
OSHA sampling results: asbestos in financial district and rubble pile; results below/exceeding limits.
Similar indexed content