Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
10/01/01 MON 10:13 FAI 212 695 5984 Bechtel URS Greiner JV @014
WTC SAMPLING REQUIRMENTS
Compound Task Frequency Sample Type Per Area Method
Lead Torch 1 per shift FuUshift- Each(4) NIOSH 7300
cutting TWA
Asbestos (a) torch 1 per shift 8 hour TWA Each (4) NIOSH 7400
cutting with TEM
(b) rubble confirmation
removal
Crystalline Rubble 1 per shift 8 hour TWA Each (4) XRD7500
silica removal (respirable)
Aromatic Rubble 2 per week 8 hour Each (4) NIOSH 1501
hydrocarbon removal
BTEX Operators 2 per week 8 hour Each (4) NIOSH 1500
Diesel Truck 1 per week 8 hour Each (4) NIOSH 5040
exhaust drivers
Carbon (a) torch 1 per shift (a)Peak Each (4) DRI with
Monoxide cutting (c) Range data record
(b)truck (c) Avg.
drivers
PAHs Rubble 2 per week Compound Each (4) GC/MS
removal identification
Formaldehy Rubble 1 per week 8 hour Each (4) NIOSH 3500
de removal
Asbestos Break area 2 per week 8 hour 2 per week TEM
Crystalline Break area 2 per week 8 hour :Total 1 per week XRD7500
Silica and
respirable
CITY_2IMC10 0_0 0 2 9 4 8 0 49
NYC-WTC_000280659
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000280659Source: NYC Law Department, mirrored locally