NYC 9/11 Public Portal Document

Sep-21-Ol 09-.37 P.O4

Page 3 of 3 IBM Corporation Office Facility

O&M CLEAN-UP or SUSPECT ACM DEBRIS 33 MAIDEN LANE i"*, 3"* and S** Floor

4. Local negative ventilation will run continuously during cleanup. Operating HEPA ventiiaion units should he placed within the fteah air intake and exhausted to the . outside.

5. All gross debris in the work area shall be considered asbestos contaminated material. Prior to removal from the work area ell ACM contaminated material shall be adequately wetted with amended water and either properly double bagged or HEPA vacuumed.

6. Detailed cleaning of the work area shall he performed using HEPA filtered vacuum equipment and/or wet clearsing. Methods that raise dust, such as dry sweeping or vacuuming with equipment not equipped with HEPA filters, will not be permitted.

7. All tools used during cleanup operations siiall be decontaminated via wet wiping and HEPA vacuuming.

8, PCM air itionitoting will be performed within and adjacent to the cleanup area during cleaning.

9, If air sa.mpiHig results indicate any airborne asbestos fiber concentrations at or above 0.01 fibers per cubic centimeters work shall be stopped immediately, and methods shail be altered to reduce the asbestos fiber concentration.

10. Once the cleanup area is inspected and determined dry and free of debris, cleaiancie air tests may be performed,

11. Following a minimum drying time of one hour after wet cleaning has been completed, an authorized and qualified individual; independent of the removal ptoject, <!.?'■ the Air Sampling Technician, Project Monitor or Design Engineer); shall determine if; the surfaces tn the work area are dry. Once the work area has been inspected and found to be dry, TEM static clearaacs air sampling may be performed.

ENVIRONMENTAL CONSULTING AND TRAINING

00236

CITY_21MC100_011971225

NYC-WTC_000418436

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418436Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →