CHAPTER 1—ASBESTOS CONTROL PROGRAM §1-105
(5) The ACM within the secured glovebag shall be wetted with amended
water prior to stripping.
(6) The bag shall be attached over duct tape which has been placed
securely around the insulation, forming a smooth seal. The bag shall be
securely attached to the insulation in a manner to prevent air transfer.
(7) The integrity ofthe glovebag seal shall be smoke tested. The contents
of the smoke tube shall be aspirated through the water port access sleeve
of the bag. After twist sealing the access sleeve, the bag shall be squeezed
gently to check for leakage points which are then taped airtight.
(8) If the insulation adjacent to the section which will be worked on is
damaged, or if the insulation terminates or is jointed or contains an elbow
adjacent to the work section, the adjacent insulation shall be wrapped in
6-mil polyethylene sheeting and sealed airtight with duct tape.
(9) After the insulation has been removed, the surface shall be sprayed
with amended water and brush-scrubbed to remove all visible ACM. The
surface, the interior of the bag, the insulation and the tools shall then be
‘ sprayed with amended water. The enclosed volume shall be misted and time
allowed for the mist to settle out before breaking the seal to remove the
glovebag.
(10) Any insulation ends created by this procedure shall be:
(i) sealed with encapsulant prior to bag removal, or
(ii) thoroughly wetted before bag removal and sealed with wettable
cloth end caps and spray glue or any combination of these materials
immediately following bag removal.
(11) . The tool pouch shall be separated from the bag prior to disposal by
twisting it and the wall to which it is attached several times, and taping
the twist to hold it in place, thus sealing the bag and the pouch which are
severed at the midpoint of the twist. Alternatively, the tools can be pulled
through with one or both glove inserts, thus turning the gloves inside out.
The glove(s) is/are then twist sealed forming a new pouch, taped and
severed mid-seal forming two separate bags.
(12) A.HEPA vacuum shall be used for evacuation of the glovebag in
preparation for removal of the bag from the surface for clean-up in the event
of a spill, and for post project clean-up.