§1-103 TITLE 15—DEPT. OF ENVIRONMENTAL PROTECTION
materials shall not be dropped. ACM shall not be dropped from a height
greater than 10 feet. Above 10 feet in height dust-free enclosed inclined chutes
may be used. Vertical or near vertical chutes are prohibited. Maximum
inclination from horizontal shall be 60 degrees.
(e) Large components removed intact that cannot be containerized shall
be maintained wet, wrapped (minimizing excess air) in at least one layer of
6-mil polyethylene sheeting, and secured by sealing with tape.
(f) After completion of all stripping work, surfaces from which asbestos
containing materials have been removed shall be cleaned (e.g. wet-brushed
and/or wet-cleaned) to remove all visible residue.
(g) After the work area has been rendered free of visible residues, a thin
coat of a pigmented (non-transparent) encapsulating agent shall be applied
to all surfaces in the work area from which ACM was removed, to seal in
nonvisible residue.
§1-103 Encapsulation Procedures- The following procedures shall be
followed for the encapsulation of ACM;
(a) Damaged and/or missing areas of existing fireproofing or insulation
materials shall be repaired with appropriate replacement materials. The
replacement material shall adhere to existing surfaces and provide a base for
application of encapsulating agents.
(b) Loose or hanging asbestos-containing materials shall be removed in
accordance with the requirements of §1-102; “Disturbance, Handling, and
Removal.”
(c) Only pigmented (non-transparent) encapsulants shown to be ratable
as acceptable or marginally acceptable on the basis of Battelle Columbus
Laboratory test procedures and rating requirements developed under the
1978 USEPA contract shall be used for encapsulation.
(d) The encapsuiant .solvent or vehicle shall not contain a volatile hydro
carbon.
(e) Latex Paint with solids content greater than 15 percent may be used
as an encapsuiant only as follows:
(1) as a lockdown sealant for coating all non-metallic surfaces, or
(2) for sealing of cementitious ACM.
(f) Encapsulants shall be field tested prior to use by applying each to a
small area to determine suitability of the material to be encapsulated.
(1) Testing is to occur only after the isolation barriers are in place,
(2) Testing shall be by the USEPA method specified in the appendix of
“Guidelines for the Use of Encapsulants on Asbestos-Containing Materials”
(June, 1981) or ASTM Standard Test Method E736-80. The encapsulated
materials shall achieve a cohesive/adhesive strength of 100 Ib/ft perpen
dicular to the surface.