NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 15 pages

Asbestos regulations, Part 763

Machine-extracted title · confidence 41%

Table of contents for asbestos in schools, 15 U.S.C. 2605 references.

NYC-WTC_000411786–000411800
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I

§762.91 (3) Except as provided in paragraphs (i)(4), and U.S. Environmental Protection Agency, Room B- (i)(5), of this section, an action to remove, encap­ 607 NEM. 401 M Street, SW.. Washington, DC, sulate, or enclose ACBM shall be considered com­ 20460, between the hours of 12 p.m. and 4 p.m plete when the average coneenlralion of asbestos weekdays excluding legal holidays. This incorpo­ of five air samples collected within the affected ration by reference was approved by the Director functional space and analyzed by the TEM method of the Federal Register in accordance with 5 in appendix A of this subpan E, is not statistically U.S.C. 552(a) and 1 CFR part 51. The method is significantly different, as determined by the Z-test incorporated as it exists on the effective date of calculation found in appendix A of this subpart E, this rule, and a notice of any change to the method from the average asbestos concentration of five air will be published in the Federal Register. samples collected ai the same lime outside the af­ (6) To determine the amount of ACBM affected fected functional space and analyzed in the same under paragraph (i)(5) of this section, the local manner, and the average asbestos concentration of education agency shall add the total square or lin­ the three field blanks described in appendix A of ear footage of ACBM within the containment bar­ this subpart E is below the filter background level, riers used IO isolate the functional space for the as defined in appendix A of this subpan E, of 70 action to remove, encapsulate, or enclose the suuctures pet square miUimeter (70 s/mm ACBM. Contiguous portions of material subject to (4) An action may also be considered complete such action conducted concurrently or at approxi­ if the volume of air drawn for each of the five mately the same time within the same school samples collected within the affected functional building shall not be separated to qualify under space is equal to or greaier than 1,199 L of air for paragraph (i)(5), of this section. a 25 mm filter or equal to or greater than 2.799 152 FR 41846, Oct. 30. 1987. as amended at 53 FR L of air for a 37 mm filter, and the average con­ 12525, Apr. 15, 1988; 60 FR 31922 June 19. 1995; 60 centration of asbestos as analyzed by the TEM FR 34465, July 3, 1995] method in appendix A of this subpart E, for the five air samples does not exceed the filter back­ §763.91 Operations and maintenance. ground level, as defined in appendix A, of 70 (a) Applicabiliry. The local education agency structures per square millimeter (70 s/mm’). If the shall implement an operations, maintenance, and average concentration of asbestos of the five air repair (O&M) program under this section when­ samples within the affected functional space ex­ ever any friable ACBM is present or assumed to ceeds 70 s/mm’, or if rhe volume of air in each be present in a building that it leases, owns, or of the samples is less than 1,199 L of air for a 25 otherwise uses as a school building. Any materia] mm filter or less than 2,799 L of air for a 37 mm identified as nonfnable ACBM or nonfriable as­ filter, the action shall be considered complete only sumed ACBM must be treated as friable ACBM when the requirements of paragraph (i)(3) or for purposes of this section when the material is (i)(5), of this section are meh about to became friable as a result of activities (5) At any time, a local education agency may performed in the school building. analyze air monitoring samples collected for clear­ (b) Worker proieciion. The protection provided ance purposes by phase contrast microscopy by EPA at 40 CFR 763.121 for worker protection (PCM) to confirm completion of removal, encap­ during asbestos abatement projects is extended to sulation, or enclosure of ACBM thai is greater employees of local education agencies who per­ than small-scale, short-duration and less than or form operations, maintenance, and repair (O&M) equal to 160 square feei or 260 linear feet. The ac­ activities involving ACM and who are not covered tion shall be considered complete when the results by the OS HA asbestos construction standard at 29 of samples collected in the affected functional CFR 1926,58 or an asbestos worker approved by space and analyzed by phase contrast microscopy OSHA under section 19 of the Occupational Safe­ using the National Institute for Occupational Safe­ ty and Health Act. Local education agencies may ty and Health (MOSH) Method 7400 entitled “Fi­ consult appendix B of this subpart if their employ­ bers" published in the NIOSH Manual of Analyt­ ees are performing operations, maintenance, and ical Methods. 3rd Edition. Second Supplement. repair activities that are of small-scale, short-dura­ August 1987, show that the concentration of fibers tion. for each of the five samples is less than or equal (c) Cleaning—(1) Inirial cleaning. Unless the to a limit of quantitation for PCM (O.OI fibers per building has been cleaned using equivalent meth­ cubic centimeter (0.01 f/cm’) of air). The method ods within the previous 6 months, all areas of a IS available for public inspection at the Office of school building where fnaole ACBM, damaged or the Federal Register, 800 North Capitol Street, significantly damaged thermal system insulation NW, Suite 700, Washington, DC, 20408, and the ACM, or friable suspected ACBM assumed to be Non-Confidential Information Center (NCIC) ACM are present shall be cleaned at least once (7407), Office of Pollution Prevention and Toxics, after the completion of the inspection required by

8

CITY_21MC100_006242928

NYC-WTC_000411797

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000411797Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →