ut ENVIRONA^NTAL I N C O n P o'tr’TT E D The First Choice jor Environmental Testing & Consulting

October ‘. 2001

Gateway i’laza Management Corporation 375 South End Avenue .New Yorl. .New York 10280 Via Facsimile

Subject:! inal Air Clearance Sampling: Gateway Plaza 375 South End Avenue Building 400 Aoaitment-lOU

Gentlemei;

ALC Environmental Incorporated (ALC) (License #00-0358) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol o determine the presence of asbestos at the above referenced project.

Based on EPA Guidelines, we collected one (1 1 bulk sample from this apanment a.nd analyzed t via Polarized Light Microscopy (PLM) Methodology. One sample collected from this apartment was found to be slightly above the regulatory limits of 1% by weight. The sample was then forwarded to a second laboratory for further analysis and was determined to be below the regulatory limits. (See Attached Results)

Approver Asbestos Abatement Inc. (License #99-1184), a certified asbestos abatement contractor hired independently by the owner, was used to clean this specific apanment.

Upon completion of the asbestos clean up procedures, a visual inspection was conducted in Apartment lOU of the 400 building at Gateway Plaza. No visible asbestos containing material (acm) or debris was observed, ALC then performed final air clearance sampling.

The areas were cleared by ALC via Transmission Electron Microscopy (TEM) Methodology. The results indicated that the work areas achieved the acceptance criteria well below <70 structures per mm2 set by the above regulations.

The air sampling and analysis were done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE H AHERA7ASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

I i 5 Wes! 3(Jth Street « 11th Floor » \ew York. .\ew York 1000! • 212.2'9 100! ■ 888.-100 Yr20 • Fax: 212 279 67-f-

Homi- 1 >1!icr the Bellevue • Suite nOO • 200 > Broad Sireet • Philadclphu P.A 1 u 102 • 2 I T " 12 tru r \ p : 15 - 'll

ivuu ALCErvirnnmenicll lOm

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, JAN. 2013

CITY_DEP_WORBY_CANNATA_SUBP_000000509

NYC-WTC_000409775

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000409775Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →