Final air results; Apt 24P, 395 Ave Building 600

Machine-extracted title · confidence 41%

Two bulk samples collected; PLM results indicate one slightly above 1% threshold; abatement noted.

NYC-WTC_000409458–000409459
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

J r aw INCORPORATED The First Choice for Environmental Testing & Consulting

January 2, 2001

Gateway Plaza Management Corporation 375 South End Avenue New York, New York 10280

Subject: Final Air Clearance Sampling: Gateway Plaza 395 South End Avenue Building 600: Apartment-24P

Gentlemen:

ALC Environmental Incorporated (ALC) (License #00-0358) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol to determine the presence of asbestos at the above referenced project.

Based on EPA Guidelines, we collected two bulk samples from this apartment and analyzed them via Polarized Light Microscopy (PLM) Methodology. One (1) sample collected from this apartment was found to be slightly above the regulatory limits of 1% by weight. (See Attached Results)

Approved Asbestos Abatement Inc. (License #99-1184), a certified asbestos abatement contractor hired independently by the owner, was used to clean this specific apartment.

Upon completion of the asbestos clean up procedures, a visual inspection was conducted in this specific apartment unit. No visible asbestos containing material (acm) or debris was observed, ALC then performed final air clearance sampling.

The areas were cleared by ALC via Transmission Electron Microscopy (TEM) Methodology. The results indicated that the work areas achieved the acceptance criteria well below <70 structures per mni2 set by the above regulations.

The air sampling and analysis were done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE IIAHERA/ASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

115 West 30th Street • 11th Floor • New York, New York 10001 • 212.279.1001 • 888.466.3620 • Fax; 212.279.6747 Home Office; The Bellevue • Suite 600 • 200 S. Broad Street • Philadelphia, PA 19102 • 215.732.9499 • 888.789.8378 • Fax: 215.732.9559 www.ALCEnvironmental.com

CONFIDENTIAL, CITY_2IMCl00_003385229 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000409458

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000409458Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →