Final air report, Building 200 apartment 23F

Machine-extracted title · confidence 32%

Final air sampling results for Apartment 23F, Building 200.

NYC-WTC_000409613–000409614
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

u ENVIRONAAEfTTAL INCOnPORATED The First Choice for Environmental Testing & Consulting

October 9. 2001

Gateway Plaza Management Corporation 375 South End Avenue New York, New York 10280 Via Facsimile

Subject; Final Air Clearance Sampling: Gateway Plaza 355 South End Avenue Building 200: Apartment-23F

Gentlemen:

ALC Environmental Incorporated (ALC) (License #00-0358) has been retained to perform bulk sampling, visual assessments & air monitoring according to the EPA Protocol to determine the presence of asbestos at the above referenced project.

Based on EPA Guidelines, we collected six (6) bulk sample from this apartment and analyzed it via Polarized Light Microscopy (PLM) Methodology. The six (6) samples collected from this apartment were found to be slightly above the regulatory limits of 1 % by weight. The sample was then forwarded to a second laboratory for further analysis and was determined to be below the regulatory limits. (See Attached Results)

Approved Asbestos Abatement Inc. (License #99-1184), a certified asbestos abatement contractor hired independently by the owner, was used to clean this specific apartment.

Upon completion of the asbestos clean up procedures, a visual inspection was conducted in Apartment 23F of the 200 building at Gateway Plaza. No visible asbestos containing material (acm) or debris was observed, ALC then performed final air clearance sampling.

The areas were cleared by ALC via Transmission Electron Microscopy (TEM) Methodology. The results indicated that the work areas achieved the acceptance criteria well below <70 structures per mm2 set by the above regulations.

The air sampling and analysis were done utilizing applicable Federal, State and City Regulations pertaining to asbestos to include Federal OSHA (29 CFR 1926.58) EPA NESHAPS (40 CFR PART 61), AND TSCA TITLE H AHERA/ASHARA (40 CFR PART 763) Asbestos Regulations; the New York State Department of Labor Industrial Code Rule 56 and the New York City Department of Environmental Protection Title 15 Asbestos Regulations.

I 15 West JOlh Street ’ 11th Floor • New York. New York 10001 • 212.270.1001 ’ 888.466.1620 • Fax: 212.270.6747

Home dlhcc: The Bellevue • Suite bOO ’ 200 S Broad Sireet • Philadelphia. P.5 NlOd • 215 732 4499 • S88 789,S37K • Fax 215 732.9559

wM tv Al ( Etivitiitinicntdl i om

CONFIDENTIAL, SUBJECTTO PROTECTIVE ORDER NO. 1, JAN. 2013

CITY_DEP_WORBY_CANNATA_SUBP_000000251

NYC-WTC_000409613

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000409613Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →