NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 12 pages

Dust characterization at WTC site, authors

Machine-extracted title · confidence 40%

Co-authored report detailing dust characterization after WTC collapse.

NYC-WTC_000407202–000407213
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

* Dust/smoke aerosol after th_e^_lla£se_of^^WTC,-_9/11/2001

added EPA 525 internal standards (Supcico) The dust and smoke extracts, which were was performed by GC with halogen-selec­ to the sample run as quality control checks blown to dryness in conical vials and refrig­ tive electrolytic conductivity detection with for rough quantitation and retention time erated, were analyzed via GC/high-resolu- multipoint calibration. Dccachlorodiphenyl quality control. A secondary identification tion mass spectrometr)' (GC/HRMS) after ether was used as an internal standard. was performed using retention time confir­ the addition of an internal standard and 2,2',4,4',5,6',6 '-Octachlorobiphenyl was mation with quality control standards, when nonane. We programmed the column tem­ added before extraction as a surrogate stan­ available. We analyzed a 1-pL aliquot of perature to separate the 2,3.7,8-TCDD con­ dard, and results were corrected for its standard with the GC/ITMS system under gener from other TCDD analytes. The tetra recovery (mean ± SD, 68.1 ± 2,02). We the same conditions used for samples and congeners had to be eluted from the column confirmed compound identities by GC/MS quality control samples. Approximately 300 after 20 min for this co occur. The seventeen ill the full scan electron ionization mode. semivolarile organic compound standards congeners of interest were then detected None of the target compounds were including EPA 525, 625, and 8270 standards with the HRMS. We identified compounds detected in the blank. (Su pel co) were injected to build the GC eluting from the GC column by the reten­ retention time library. We defined a reten­ tion rime reference obtained from the corre­ Results tion time match as an analyte compound sponding labeled isotope and rhe ion ratio of The general characteristics of each total set­ eluting within ± 5 sec of the standard sample the measured ions during selective ion tled dust and smoke sample are shown in retention time. All reported compounds met response. We calculated the concentration of Tabic J; these characteristics indicate that these criteria. each congener by using the relative response the composition of major components in Bolychlorifiatec/ e/ioxins (PCDDs) ant/ factors cf each native congener to its rcspcc- each sample were similar, with slight diTer- frrans (PCDfs). We used U.S. Environmennl tivc 13C12-labclcd congener. ences in total composition for the Market Protection Agency (EPA) Methods 1613 and Standards used in the analyses were con- Street sample. Generally, the samples were RCRA SW846 Method 8290 for dioxin centration of stock and spiking solutions very light and fluffy, and were white to pink­ analyses {IS,12). In these methods, a clean containing PCDDs/PCDFs and labeled ish-gray, The general physical ap^Tcarance of extraction thimble was charged with 5.0 g of compounds. We included a cleanup stan­ the Market Street sample is shown in Figure 100/200-mesh silica topped with 100 g of dard (Ci4, 2.3 J.8-TCOD, 0.8 ng/mL) and 2 as an example. The mass of each sample quartz sand. The silica layer was left undis­ internal standards (CI2. 1.2,3,4-TCDD. was dominated by nonflhrous material and turbed throughout the extraction process. 200 ng/mL; and CI2, 1,2,3.7,8,9-bexaCpD, construction debris, and the Cortlandt and TItc thimble was placed in a clean extractor 200 ng/mL). Cherry Street samples contained approxi­ with 30-40 mL of toluene in the receiver and Brorninnte^ c/iphenyl ethers. The analytic mately 0.8% asbestos. In contrast, of the 200-250 mL of toluene in the flask. The wet methodology for detecting brominated mass collected, the Market Street sample sample, filter, and/or disk were loaded and diphenyls and diphenyl ethers have been contained 3-0% asbestos. We found only any nonaqueous liquid removed. The described previously {20). Briefly, we subjected background levels of alpha radionuclide remaining sample was placed in the thimble total dust samples to enhanced solvent extrac­ activity by liquid scintillation counter analy­ and manually mixed into the sand layer with tion using methylene chloride. Extracts were sis of all three samples. Beta activity was a clean metal spatula, carefully breaking up purified by size exclusion and silica gel liquid slightly elevated, but not more than twice any large lumps of sample. chromatography. Compound quantification the background level. There were no levels of gamma activity > 1 Bq/g except for natu­ Table 1. General characteristics ol settled dust and smoke samples (percent by mass) Irom the first days rally occurring potassium-40. after the collapse and fires of the WTC. The pH of an aqueous suspension of Street each sample was > 7; the Cortlandt Street Sample Cortlandt Cherry Market sample had a pH of ITS. Both rhe Cherry Color Pinkish gray Pinkish gray Pinkish gray and Market Street samples had a pH of *“9 pH 11 5 9.2 93 (Table 1). Significant amounts (==10% of rhe Nonfibei (cement/caibon, 50.0 492 37.0 mass) of cellulose were found in all three Glass fiber (%)' 400 400 400 samples. This observation is consistent with Cellulose (To) ’ 92 100 200 the release of large amounts of disintegrated Chrysotile asbestos (%) ’ 08 0.8 3.0 paper and other products that were origi­ Aerodynamically separated sample (% mass) <2.5 pm diameter 1.12 088 1.30 nally pan of the indoor work environments. 2 5-10 pm diameter 0 35 030 040 10-53 pm diameter 37 03 46 61 34.69 > 53 pm diameter 61 50 62 21 63 60 •.uribi Sieved sample |% mass) <75 pm diameter 3800 30 00 37.00 75-300 pm diameter 46 00 49 00 42.00 >300 pm diameter 1600 23 00 2100 Anion3/caticns(ng/g) Fluoride 220 70 ND Chloride 800 270 220 Nitrate 330 NO NO Sulfate 41,400 35,200 42,100 Calcium 18,200 14,000 17,700 Sodium 400 200 130 Potassium 60 170 270 Figure 2, The general appearance of the bulk dust ND, not detectable. collected at the Market Street location east of the *Values teponed to LC. Chen by the Ambient Group, INC (New Voik, NY), measured by polanred light microscopy WTC site. Dust samples from the other two sites |400-45t)x). were similar in appearance. Magnification = 4x.

Environmental Health Perspectives • volume 1101 number 71 July 2002 707

CITY_21MC100_006646047

NYC-WTC_000407206

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407206Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →