Dust characterization at WTC site, authors

Machine-extracted title · confidence 40%

Co-authored report detailing dust characterization after WTC collapse.

NYC-WTC_000407202–000407213
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Articles • Lioy et al.

Wc detected no differences between the The findings of skin cells was consistent with construction debris (including cement, ver­ exposed copper mirrors and the controls, rhe types of particles usually found in dust in miculite, plaster, synthetic foam, glass frag­ indicating that these dust samples were not the indoor environnKnr. ments, mineral wool fibers, paint parcicles, corrosive toward base metals. This finding is Approximately 35% of the volume of the glass fibers, metals, calcite grams, and paper consistent with the pH measurements, saniple was in the form of loosely consoli­ fragments), quartz grains, low-temperature Mor/iMogie a/iafyses. Derailed morpho­ dated clumps of fibrous lint, of which the combustion material (including charred logic analyses of each sample supported the greatest portion was glass fibers. An example woody fragments), and metal flakes. Wc csti- general characterizations presented in Table 1. of the typical form of rhe glass fibers is shown mared char chry'sorile asbestos fibers com­ Cortlandt Street sample. The Cortlandt in Figure 4. In many cases the width was s 1 prised < 1% of the sample by volume. Much Street sample was mainly composed of con- pm (to > 10 pm), and rhe length ranged of the chrysotile asbestos had carbonate stmetion debris [including vermiculite, plas­ from 5 to 100 pm. The fiber shown in Figure binder adhered to it. We observed some hair ter, synthetic foam, glass fragments, paint 4 is not a “clean” glass fiber; other materials fibers and tarry fragments in the sample. particles, glass fibers, lead (bigure 3), calcite are agglomerated along rhe rod. This is typi­ Approximately 10?-b of the volume of the grains, and paper fragments], quartz grains, cal of features noted for many different types sample was in the form of loosely consoli­ low-temperature combustion- material of particles in each sample. 7'hc SEM analysis dated clumps of fibrous lint, of which the (including charred woody fragments), and of the fraction < 75 pm in diameter revealed greatest portion w’as glass fibers. The SEM glass shards. Chrysotile asbestos fibers were many glass fibers and cement panicles, some analysis of the fraction <75 pm in diameter c.stimatcd to comprise < 1% of the sample by in a fibrous form containing calcium, silicon, revealed many glass fibers and cement parti­ volume, and much of the chrysotile adhered and sulfur, and some particles were com­ cles. some in a fibrous form, containing cal­ to carbonate binder. Some skin cells and posed of calcium carbonate (Figure 5). cium, silicon, and sulfur. dyed cotton fibers were present {5,21-23}. Chrysotile asbestos fibers, identified by Wc used SEM and TEM co examine transmission electron microscopy (TEM), chrysotile asbestos fibers, lead paint frag­ were found in the < 75-pm fraction. None ments, iron-chromium particles, and soot of the analyzed particles contained lead, particles found in the < 75-pm fraction. The chromium, cadmium, or mercuty, although sooc parricles were in the stibmicron size chromium and cadmium were quantified in range (Figure 6). No particles containing this sample by ICP/MS analyses. cadmium (detected by ICP/MS) or mercury Cherry Avenue sample. The Cherry were found at less than minimum detection Avenue sample is mainly composed of limits in the 1,000 particles analyzed from rhi.s sample. Market Street sample. The Market Street sample was also composed of con- stniction debris (including vermiculite, plas­ ter, synthetic foam, glass fragments, paint parricles, mineral wool fibers, glass fibers, calcite grains, and paper fragments), quartz grains, low-remperarurc combusrion material (including charred woody fragments), and Figure 3. Appearance of lead from the Cortland! metal Hakes. Chiysotile asbestos fibers made Street sample. up < 1% of the sample by volume, and much of the chtysotile adhered to carbonate binder. This result is different from the bulk Figure 5. Coarse calcium carbonate particle mass results, which indicated 3.0% asbestos; detected in the Cortland! Slreei sample. this indicates that the sample was not homo­ geneous. Some dyed cotton fibers, tarry frag­ ments, pollen grains, and metal flakes were also present. Approximately 10% of the vol­ ume of the sample was in the form of loosely Class fibei consolidated clumps of fibrous linr, of which A , ♦ i,**' the greatest portion was glass fibers. The -ft * -iK' SEM analysis of the fraction < 75 pm in AT-- diameter revealed many glass fibers and cement particles, some in a fibrous form containing calcium, silicon, and sulfur. Chiy'sotile asbestos fibers, identified by TEM, were found in the fine fraction. We found no particles containing lead, chromium, cadmium, or mert;ury in the single particles analyzed from the Market Street sample, MVA4aO8 L1617 0.2 pm although all but mercury were detected by MVA4808 L1618 Park 5 pm the ICP/MS analyses. Market 4-1 Figure G. A soot particle containing coagulated The morphologic differences between Figure fl. Glass fiber defected in the Market Street ultra-line particles detected in the Cherry Street each of rhe collected samples were minor sample. sample. and could be atrributed to the fact that we

708 VOLUME no 1 NUMBER? I July 2002 • Environmental Health Perspectives

CITY_21MC100_006646048

NYC-\/VTC_000407207

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407207Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →