added EPA 525 internal standards (Supelco) The dust and smoke extracts, which were was performed by GC with halogen-selec
to the sample run as quality control checks blown to dryness in conical vials and refrig tive electrolytic conductivity detection with
for rough quantitation and retention time erated, were analyzed via GC/high-resolu- multipoint calibration. Decachlorodiphenyl
quality control. A secondary identification tion mass spectrometry (GC/HRMS) after ether was used as an internal standard.
was performed using retention time confir the addition of an internal standard and 2,2',4,4',5,6',6'-Octachlorobiphenyl was
mation with quality control standards, when nonane. We programmed the column tem added before extraction as a surrogate stan
available. We analyzed a 1-pL aliquot of perature to separate the 2,3,7,8-TCDD con dard, and results were corrected for its
standard with the GC/ITMS system under gener from other TCDD analytes. The tetra recovery (mean ± SD, 68.1 ± 2.02). We
the same conditions used for samples and congeners had to be eluted from the column confirmed compound identities by GC/MS
quality control samples. Approximately 300 after 20 min for this to occur. The seventeen in the full scan electron ionization mode.
semivolatile organic compound standards congeners of interest were then detected None of the target compounds were
including EPA 525, 625, and 8270 standards with the HRMS. We identified compounds detected in the blank.
(Supelco) were injected to build the GC eluting from the GC column by the reten
retention time library. We defined a reten tion time reference obtained from the corre Results
tion time match as an analyte compound sponding labeled isotope and the ion ratio of The general characteristics of each total set
eluting within ± 5 sec of the standard sample the measured ions during selective ion tled dust and smoke sample are shown in
retention time. All reported compounds met response. We calculated the concentration of Table 1; these characteristics indicate that
these criteria. each congener by using the relative response the composition of major components in
Polychlorinated dioxins (PCDDs) and factors of each native congener to its respec each sample were similar, with slight differ
Jurans (PCDFs). We used U.S. Environmental tive 13C12-labeled congener. ences in total composition for the Market
Protecrinn Agency (F.P.A) Methods 1613 and Standards used in the analyses were con Street sample. Generally, the samples were
RCRA SW846 Method 8290 for dioxin centration of stock and spiking solutions very light and fluffy, and were white to pink
analyses In these methods, a clean containing PCDDs/PCDFs and labeled ish-gray. The general physical appearance of
extraction thimble was charged with 5.0 g of compounds. We included a cleanup stan the Market Street sample is shown in Figure
100/200-mcsh silica topped with 100 g of dard (CI4, 2,3,7,8-TCDD, 0.8 ng/mL) and 2 as an example. The mass of each sample
quartz sand. The silica layer was left undis internal standards (CI2, 1,2,3,4-TCDD, was dominated by nonfibrous material and
turbed throughout the extraction process. 200 ng/mL; and Cl., 1,2,3,7,8,9-hexaCDD, construction debris, and the Cortlandt and
The thimble was placed in a clean extractor 200 ng/mL). Cherry Street samples contained approxi
with 30—40 mL of toluene in the receiver and Brominated diphenyl ethers. The analytic mately 0.8% asbestos. In contrast, of the
200—250 mL of toluene in the flask T he wet methodology for detecting brominated mass collected, the Market Street sample
sample, filter, and/or disk were loaded and diphenyls and diphenyl ethers have been contained 3.0% asbestos. We found only
any nonaqueous liquid removed. The described previously (20). Briefly, we subjected background levels of alpha radionuclide
remaining sample was placed in the thimble total dust samples to enhanced solvent extrac activity by liquid scintillation counter analy
and manually mixed into the sand layer with tion using methylene chloride. Extracts were sis of all three samples. Beta activity was
a dean metal spatula, carefully breaking up purified by size exclusion and silica gel liquid slightly elevated, but not more than twice
any large lumps of sample. chromatography. Compound quantification the background level. There were no levels
of gamma activity > I Bq/g except for natu
Table 1. General characteristics of settled dust and smoke samples (percent by mass) from the first days rally occurring potassium-40.
after the collapse and fires of the WTC. The pH of an aqueous suspension of
Street each sample was > 7; the Cortlandt Street
Sample Cortlandt Cherry Market sample had a pH of 11.5. Both the Cherry
Color Pinkish gray Pinkish gray Pinkish gray and Market Street samples had a pH of -=9
Off 11.5 9.2 9.3 (Table 1). Significant amounts (•=10% of the
Nonfiber Icement/cartron: %)^ 50.0 49.2 37.0 mass) of cellulose were found in all three
Glass fiber (%) ’ 40.0 40.0 40.0 samples. This observation is consistent with
Cellulose (%) 9.2 10.0 20.0 the release of large amounts of disintegrated
Chrysotile asbestos (%) ’ 0.8 0.8 3.0
Aerodynamically separated sample (% mass) paper and other products that were origi
< 2.5 pm diameter 1.12 0.88 1.30 nally part of the indoor work environments.
2.5-10 pm diameter 0.35 0.30 0.40
10-53 pm diameter 37.03 46.61 34.69
> 53 pm diameter 61.50 62.21 63.60
Sieved sample (% mass)
< 76 pm diameter 38,00 30.00 37.00
a &
75-300 pm diameter 4600 49.00 42.00
> 300 pm diameter 16.00 23.00 21.00
Anions/cations (ng/g)
Fluoride 220 70 ND
UI tiuriue 800 2/0 220
Nitrate 330 ND ND
Sulfate 41,400 35,200 42,100
Calcium 18,200 14,000 17.700
Sodium 400 200 130
Potassium 60 170 270 Figure 2. The general appearance of the bulk dust
M D, not detectable. collected at the Market Street location east of the
^*1. measured by polarized light microscopy WTC site. Oust samples from the other two sites
I ^*-UU H JUX ).
were similar in appearance. Magnification = 4x.
Environmental Healrii Perspectives • volume 1101 number 7 I July 2002 707