NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 22, 2002
« Wipe Samples for Dioxins Page 2
H. S. of Economics & Finance (M833) ATC Project No. 15-19125-0291
DIOXIN WIPE SAMPLE RESULTS
(2,3,7,8 TCDD EQUIVALENTS) - Nanograms per square meter (ng/m^)
April 6, 2002
Main Lobby/DXl
5th Floor Hall by Stair B/DX2 0.00062
lOhi Floor by Stair B/DX3 0.00068
April 20,2002
Main Lobby/DXl
5th Floor Hall by Stair B/DX2 0.0018
10th Floor by Stair B/DX3 0.0029
AprU 27,2002
Main Lobby/DXl
5th Floor Hall by Stair B/DX2 0.000078
10th Floor by Stair B/DX3 0.00O48
The New York State Department of Health (NYSDOH) established guidelines for dioxin for the
re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH
guideline for dioxin on surfaces is 25 ng/m^.
On April 6, the concentrations on indoor surfaces ranged from 0.00027 to 0.00068 ng/m^.
On April 20, the concentrations on indoor surfaces ranged from 0.000037 to 0.0018 ng/m^. On
April 27, the concentrations on indoor surfaces ranged from 0.00 to 0.000078 ng/m2. The levels
found in all these samples are below the NYSDOH guideline of 25 ng/m^.
It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples
were deposited. Dioxin samples were not collected from this school prior to January 14, 2002.
CITY_21MC1OO_OO29OO572
NYC-WTC_000404699