NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 6, 2002
Wipe Samples for Dioxins Page 2
H. S. of Economics & Finance (M833) ATCProiectNo. 15-19125-0291
DIOXIN WIPE SAMPLE RESULTS
(2,3, 7, 8 TCDD EQUIVALENTS) - Nanograms per square meter (ng/m^)
March 16, 2002
HUB IM ilinnb " mi’ ■"*1
Main Lobby/DXl 1)7)0033
5th Floor Hall by Stair B/DX2 0.00023
10th Floor by Stair B/DX3 07)0015
March 23,2002
Is
Main Lobby/DXl
5th Floor Hall by Stair B/DX2 0.00050
10th Floor by Stair B/DX3 0.00023
March 30,2002
!
•yaw MM * Si
Main Lobby/DXl WK)3^
5th Floor Hall by Stair B/DX2 0.00029
10th Floor by Stair B/DX3 I).00
The New York State Department of Health (NYSDOH) established guidelines for dioxin for the
re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH
guideline for dioxin on surfaces is 25 ng/m^.
On March 16, the concentrations on indoor surfaces ranged from 0.00015 to 0.00033 ng/m^.
On March 23, 2002, the concentrations on indoor surfaces ranged from 0.00023 to 0.00054
ng/m2. On March 30, the concentrations on indoor surfaces ranged from 0.00 to 0.00031 ng/m2.
The levels found in all these samples are below the NYSDOH guideline of 25 ng/m^.
It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples
were deposited. Dioxin samples were not collected from this school prior to January 14, 2002.