May 13, 2002
Mr. Bernard P. Orlan
Director, Environmental Health & Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101 -4008
Re; Wipe Samples for Dioxin
High School of Economics and Finance (M833)
ATC Project No. lS-19125-0291
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of the results of the wipe samples
for polychlorinated dibenzo-p-dioxins (PCDDs)and dibenzofurans (PCDFs) collected on April
13, 2002, at the referenced location. The New York City Board of Education (BOE) requested
these samples to evaluate possible contamination in the school building.
SCOPE OF WORK
Wagdi Abdelshahid, Industrial Hygienist of ATC’s New York City office, collected the samples
using gauze pads and hexane as a solvent. The pads and solvent were provided and samples
were analyzed by Pace Analytical Services, Inc. (Pace) of Minneapolis, MN, a laboratory
experienced in dioxin analysis. The analysis was performed by modified EPA Method 8290
using combined capillary column gas chromatography/high resolution mass spectrometry.
The sampling was performed consistent with generally accepted industrial hygiene practices.
There were inherent limitations created by constraints of time, operational and work practice
variability, variations in contaminant concentrations, and sampling and analytical accuracy. The
results of the sampling represent conditions found on the dates the samples were collected.
WIPE SAMPLING RESULTS
ATC submitted three (3) wipe samples for PCDDs/PCDFs to Pace for analysis. A copy of the
laboratory report is provided in the Attachment. Samples were taken from surfaces throughout
the building. The area of each sample was one square meter (1 m2).
Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer
were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by
multiplying by an established equivalency factor. This provides a single value (in nanograms)
for the analytical results for each sample. The sample locations and concentrations are shown in
the table.