Wipe sample dioxin analysis report, BOE

Machine-extracted title · confidence 56%

ATC report of wipe samples for dioxin at a NYC high school, 2002.

NYC-WTC_000404658–000404659
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document 104 East 25th St.. 10th Floor New York. New York 10010 www.atc-enviro com 2123538280 Fax 212.353.8306 ASSOCIATES INC.

April 17,2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101 -4008

Re; Wipe Samples for Dioxin High School of Economics and Finance (M833) ATC Project No. 15-19125-0291

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of the results of the wipe samples for polychlorinated dibenzo-p-dioxins (PCDDs)and dibenzofurans (PCDFs) collected on March 8, 2002, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination in the school building.

SCOPE OF WORK

Wagdi Abdelshahid, Industrial Hygienist of ATC’s New York City office, collected the samples using gauze pads and hexane as a solvent. The pads and solvent were provided and samples were analyzed by Pace Analytical Services, Inc. (Pace) of Minneapolis, MN, a laboratory experienced in dioxin analysis. The analysis was performed by modified EPA Method 8290 using combined capillary column gas chromatography/high resolution mass spectrometry.

The sampling was performed consistent with generally accepted industrial hygiene practices. There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates the samples were collected.

WIPE SAMPLING RESULTS

ATC submitted three (3) wipe samples for PCDDs/PCDFs to Pace for analysis. A copy of the laboratory report is provided in the Attachment. Samples were taken from surfaces throughout the building. The area of each sample was one square meter (1 m2).

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample. The sample locations and concentrations are shown in the table.

CITY_21MC100_002900501

NYC-WTC_000404658

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000404658Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000214137

Report providing analytical results for polychlorinated dibenzo-p-dioxins and dibenzofurans from surface wipe samples collected at the school.

Similar indexed content

PCDD/PCDF wipe sample results, Jun 2002

NYC-WTC_000197426

Laboratory report from ATC Associates detailing polychlorinated dibenzo-p-dioxins and furans analysis of wipe samples from a school.

Similar indexed content

PCDD/PCDF wipe sample results, May 2002

NYC-WTC_000197428

Laboratory report from ATC Associates detailing polychlorinated dibenzo-p-dioxins and furans analysis of wipe samples from a school.

Similar indexed content

Wipe sample dioxin results, BOE

NYC-WTC_000404690

ATC report of wipe samples for dioxin at High School of Economics and Finance, 2002.

Similar indexed content

NYC-WTC_000230525

Laboratory report detailing polychlorinated dibenzo-p-dioxins and dibenzofurans analysis from wipe samples collected in September 2002.

Similar indexed content

Compare copies and versions →