NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street-Suite 200
Minneapolis, MN 55414
mAnaIvtical Method 8290 Analysis Result® Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client's Sample ID ATC-0316-M833-DX2
Lab Sample ID 103398913
Filename U20406A_05
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/16/2002
I CAL Date 03/25/2002 Received 03/19/2002
CCal Filename(s) U204056A_01 & U20406A_08 Extracted 04/01/2002
Method Blank ID BLANK-1546 Analyzed 04/06/2002 21:28
) Native Cone EiMPC LBL Interna! ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF ND 0.0029 A 2,3,7,8-TCDF-13C 2.00 58
Total TCDF 0.0059 0.0020 J 2,3,7,8-TCDD-13C 2.00 55
1,2,3,7,8-PeCDF-13C 2.00 58
2.3.7,8-TCDD ND 0.0029 A 2,3,4,7,8-PeCDF-13C 2.00 53
Total TCDD 0.0240 0.0020 1,2,3,7,8-PeCDD-13C 2.00 52
1 1,2,3,7,8-PeCDF
2,3.4,7,8-PgCDF
ND
ND
0.0100
0.0100
1,2,3,4,7,8-HxCDF-13C
.1,2,3,6,7,8-HxCDF-13C
2,3,4,6,7,8-HxCDF-13C
2.00
2.00
2.00
80
72
65
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 66
1,2,3,4,7,8-HxCDD-13C 2.00 72
1,2,3,7,8-PeCDD ND 0.0100 1,2.3,6,7,8-HxCDD-13C 2.00 66
Total PeCDD ND 0.0100 1,2,3,4,6.7,8-HpCDF-13C 2.00 66
1,2.3,4,7,8,9-HpCDF-13C 2.00 52
1
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3.4,6,7,8-HpCDD-13C 2.00 56.
) 1.2,3,6.7.8-HxCDF ND 0.0100 OCDD-13C 4.00 44
2,3,4,6,7,8-HxCDF ND 0.0100
1,2.3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HkCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37C14 0.20 62
1.2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2.3,4,6.7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7.8,9-HpCDF ND 0.0100 Equivalence: 0.00023 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0150 0.0100 J
Total HpCDD 0.0400 0.0100 J
OCDF ND 0.0200
OCDD 0.0810 0.0200 BJ
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis “ = See Discussion
Report No.... 02-1055247
REPORT OF LABORATORY ANALYSDS
This report shall not be reproduced, except in full,
without ths written consent of Pace Analytical Services, Inc.
CITY_21MC100_002898140
NYC-WTC_000402668
OCR can misread numbers and units. Confirm readings against the page image before using them.