NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
TM
Tel: 612-607-1700
Fax: 612- 607-6444
M©th©d 8290 AnaHysfis ResuBte
Client - ATC
Client's Sample ID ATC-0316-M833-DX3
Lab Sample ID 103398921
Filename U20406A_06
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/16/2002
ICAL Date 03/25/2002 Received 03/19/2002
CCal Filename(s) U204056A_01 & U20406A_08 Extracted 04/01/2002
Method Blank ID F20407A_07 Analyzed 04/06/2002 22:15
Wativ© Comie EMPC LRL Internal ng'® PereenH
!somers ng/m2 ng/m2 ng/m2 Steodards Addled Recovery
2,3.7,8-TCDF ND 0.0028 A 2,3,7,8-TCDF-13C 2.00 42
Total TCDF 0.0064 0.0020 J 2,3,7,8-TCDD-13C 2.00 40
1,2,3,7,8-PeCDF-13C 2.00 46
2,3,7,8-TCDD ND 0.0062 A 2.3,4,7.8-PeCDF-13C 2.00 43
nr Total TCDD ND 0.0020 1,2,3,7,8-PeCDD-13C 2.00 42
1,2,3.4,7,8-HxCDF-13C 2.00 58
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 56
2,3,4,7,8-PeCDF ND 0.0100 2.3,4,6,7,8-HxCDF-13C 2.00 48
1,2,3,7,8,9-HxCDF-13C 2.00 50
1 Total PeCDF
1,2,3,7,8-PeCDD
Total PeCDD
ND
ND
ND
0.0100
0.0100
0.0100
1,2,3,4,7,8-HxCDD"13C
1,2.3,6,7.8-HxCDD-13C
1,2,3,4,6,7,8-HpCDF-13C
2.00
2.00
2.00
58
45
52
1,2,3,4,7,8,9-HpCDF-13C 2.00 42
1,2,3,4,7,8-HxCDF ND 0.0100 1.2,3,4,6,7,8-HpCDD-13C 2.00 45
1,2,3.6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 36 P
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8.9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 43
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8.9-HxCDD ND - 0.0100
Total HxCDD 0.0200 0.0100 J
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00015 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
0.0150 0.0100 J
J 1,2,3,4,6,7,8-HpCDD
Total HpCDD
OCDF
0.0360
ND —
0.0100 J
0.0200
OCDD ---- 0.099 0.0200 I
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis “ = See Discussion
Report No.... 02-1055247
I
I REPORT ©F [LABORATORY ANALYSBS
J
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC1OO_OO2898141
NYC-WTC_000402669
OCR can misread numbers and units. Confirm readings against the page image before using them.