Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
/QfQceAnalyticar Tel; 612-607-1700
Far 612- 607-6444
Method
I 8290 Analysis Results
Client - ATC
Client's Sample ID ATC-0316-M833-DX1
Lab Sample ID 103398905
Filename U20406A_04
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/16/2002
I CAL Date 03/25/2002 Received 03/19/2002
CCal Filename(s) U204056A_01 & U20406A_08 Extracted 04/01/2002
Method Blank ID BLANK-1546 Analyzed 04/06/2002 20:35
Native Cone EMPC LRL Interna! ng's Percent
isomers ng/m2 ng/m2 ng/m2 Standards Adde& Recovery
2,3,7,8-TCDF ND ---- 0.0020 2,3,7,8-TCDF-13C 2.00 64
Total TCDF 0.016 ---- 0.0020 2,3,7,8-TCDD-13C 2.00 63
1,2,3,7,8-PeCDF-13C 2.00 66
2,3,7.8-TCDD ND 0.0022 A 2.3,4,7,8-PeCDF-13C 2.00 63
Total TCDD 0.037 0.0020 1,2,3,7,8-PeCDD-13C 2.00 69
1,2,3,4,7,8-HxCDF-13C 2.00 84
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 74
2,3.4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 81
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 73
1,2,3,4,7,8-HxCDD-13C 2.00 87
1.2,3,7,8-PeCDD ND 0.0100 1,2.3,6,7,8-HxCDD-13C 2.00 72
Total PeCDD ND 0.0100 1.2,3,4,6,7,8-HpCDF-13C 2.00 90
1,2,3,4,7,8,9-HpCDF-13C 2.00 64
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 67
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 63
2.3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 72
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.016 0.0100 J
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00033 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.018 0.0100 J
Total HpCDD 0.038 0.0100 J
OCDF ND 0.0200
OCDD 0.150 0.0200 B
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interferenc®
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA=Not Applicabla
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1055247
REPORT OF LABORATORY ANALYSE
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.