NYC 9/11 Public Portal Document Psce Analytical Services, Inc. 1700 Elm Street, Suite 200 mAnalyticar Minneapolis, MN 55414 Phone: 612.607.1700 mm.pacelabs.eom REPORT OF: CHEMICAL ANALYSES Fax: 612.807.6444

PROJECT: PCDD/PCDF ANALYSES DATE: April 5, 2002

PAGE: 5 REPORT MO: 02-1055017

PCDD/PCDF Quantification and Calculations (Cont.) Each pair of ion mass peaks in the selected-ion-current chromatograms was evaluated manually to determine if it met the criteria for a PCDD or PCDF isomer. Areas of all peaks exhibiting correct ion ratios, having retention times within the correct windows, and having areas corresponding to concentrations in the range covered by the initial calibration were then summed for calculations of total congener concentrations. The toxic equivalence of each sample was calculated using the factors listed in Table 5.

A limit of detection (LOD) based on producing a signal that is 2.5 times the noise level, was calculated for each undetected 2,3,7,8-substituted isomer of any tetra through octa chlorinated congener class. The noise heights used to calculate the detection limits were measured at the retention time of the specific isomer. The formula used for calculating the LOD is:

Hn X Qis X 2.5 LOD = His X W X Rf where:

LOD Single isomer limit of detection , Hn Sum of noise heights at native isomer retention time Qis Quantity of labeled internal standard His Sum of peak heights for labeled internal standard W Sample amount R? Response factor

The recovery of the 2,3,7,8-TCDD-^’Cl4 enrichment efficiency standard and each ’^Cij-labeled internal standard, relative to either 1,2,3,4-TCDD-’^Ci2 or 1,2,3,7,8,9-HxCDD-^^Ci2, was calculated using the following equation:

Ais X Qrs x 100% %R = Rfr X Ars x Qis where:

%R = Percent recovery of labeled internal standard Ais = Sum of integrated areas of labeled internal standard Qrs = Quantity of recovery standard Ars = Sum of integrated areas of recovery standard Rfr = Response factor of the specific labeled internal standard relative to the recovery standard Qis = Quantity of the labeled internal standard congener added to the sample

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

Znebds CITY_21MC100_002898115

NYC-WTC_000402645

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000402645Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000228425

Comprehensive laboratory report containing results for environmental testing conducted by Pace Analytical Services for a New York City Board of Education project.

Similar indexed content

PCDD/PCDF lab analysis results, Jan 2002

NYC-WTC_000226877

Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.

Similar indexed content

Compare copies and versions →