Pace Analytical lab report set, 22 pages, lab analysis, ATC project.

NYC-WTC_000402640–000402661
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Pace Anslytical Servlees, Inc. 1700 Elm Street, Suite 200 ^Analytical' Minneapolis, MN 55414 Phone: 612.607.1700 tsfm.pac8labs.com REPORT OF: CHEMiCAi. ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF AIMALYSES DATE: April 5, 2002

PAOE: 4 REPORT MO: 02-1055017

PCDD/PCDF QuantifisatiorB and Sakyjations

The PCDD/PCDF isomers were quantified by comparison of their responses to the responses of the labeled internal standards. Relative response factors were calculated from analyses of standard mixtures containing representatives of each of the PCDD/PCDF congener classes at five concentration levels, and each of the internal standards at one concentration level, as shown in Table 4. The PCDD/PCDF response factors were calculated by comparing the sum of the responses from the two ion masses monitored for each chlorine congener class to the sum of the responses from the two ion masses of the corresponding isotopically labeled internal standard. The formula for the response factor calculation is:

An X Qis Rf = Ais X Qn

where:

- Rf = Response factor An = Sum of integrated areas for native isomer Qis = Quantity of labeled internal standard ' Ais = Sum of integrated areas for labeled internal standard ... Qn = Quantity of native isomer

The levels of PCDD/PCDF in each sample were quantified using the following equation:

An X Qis C = Ais X W X Rf where:

C = Concentration of target isomer or congener class An = Sum of integrated areas for the target isomer or congener class Qis = Quantity of labeled internal standard added to the sample Ais = Sum of integrated areas for the labeled internal standard W = Sample amount Rf = Response factor

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

/nebcs ’ CITY_21MC100_002898114

NYC-WTC_000402644

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000402644Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000228425

Comprehensive laboratory report containing results for environmental testing conducted by Pace Analytical Services for a New York City Board of Education project.

Similar indexed content

PCDD/PCDF lab analysis results, Jan 2002

NYC-WTC_000226877

Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.

Similar indexed content

Compare copies and versions →