NYC-WTC_000311190
ATC report on indoor air quality measurements at Stuyvesant High School (M477).
10 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC IAQ measurements report for Stuyvesant High School dated January 2, 2002.
NYC-WTC_000401735–000401738OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
sampling and analytical accuracy. The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.
EVALUATION CRITERIA
Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:
yenli/alion for Accepfab/e Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).
■Table I lists target guidelines for the parameters that ATC'evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.
TABLE 1 TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED
PARA.METER TARGET LEVEL AGENCY OR ORGANIZATION • , ' . Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon Monoxide 9 ppm ASHRAE 62 -(adopted from (CO) USEPA NPAAQS) ■'________ Respirable. 65 micrograms per cubic meter USEPA NPAAQS Particulates (PM?.5) of air (pg/m-’) 24-h6ur average Temperature Summer: 73-79°F at 50% RH ASHRAE 55 Winter; 68-75°F at 50% RH Relative Humidity 30 - 60 % ASHRAE55 Total Volatile I ppm Organic Compounds ' AIHA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA.'= American Industrial Hygiene Association-
ReaL-Time Environmental Measurements
ATC collected one hundred and twenty-seven (127) sets of real-time environmental measurements consisting of one hundred and twenty-five (125) in the school building and two (2) outdoors. All ten floors of the school were surveyed.' These results are described below. Field data sheets are found in Attachment I. Readings began at 7:45 A.M. and concluded after 3:40 P..M.
CITY_21MC100_002897685
NYC-WTC_OOO4O1736
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000311190
ATC report on indoor air quality measurements at Stuyvesant High School (M477).
10 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311194
ATC report of indoor air quality measurements at Stuyvesant High School (M477).
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401739
Indoor air quality report for Stuyvesant High School, January 2002.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401743
Indoor air quality measurements report for Stuyvesant High School, January 8, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255777
ATC memo detailing IAQ measurements at Stuyvesant High School.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401506
Indoor air quality measurements collected December 17, 2001 at Stuyvesant High School.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273995
December 2001 IAQ measurements at Stuyvesant High School with BOE contact.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274045
December 20, 2001 IAQ measurements at Stuyvesant High School for BOE.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401484
Indoor air quality measurements collected December 12, 2001 at Stuyvesant High School.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255518
IAQ measurements reported for Stuyvesant High School; December 10, 2001.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401790
ATC reports IAQ measurements taken January 11, 2002 at Stuyvesant High School.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255522
Indoor air quality measurements at Stuyvesant High School, December 12, 2001.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000401739
Indoor air quality report for Stuyvesant High School, January 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000179059
Transmittal letter from ATC Associates to the NYC Board of Education enclosing an indoor air quality report for Stuyvesant High School.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273995
December 2001 IAQ measurements at Stuyvesant High School with BOE contact.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311194
ATC report of indoor air quality measurements at Stuyvesant High School (M477).
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401506
Indoor air quality measurements collected December 17, 2001 at Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000255777
ATC memo detailing IAQ measurements at Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000311190
ATC report on indoor air quality measurements at Stuyvesant High School (M477).
Similar indexed content
NYC-WTC_000311194
ATC report of indoor air quality measurements at Stuyvesant High School (M477).
Similar indexed content
Indoor air quality report for Stuyvesant High School, January 2002.
Similar indexed content
NYC-WTC_000401743
Indoor air quality measurements report for Stuyvesant High School, January 8, 2002.
Similar indexed content
NYC-WTC_000255777
ATC memo detailing IAQ measurements at Stuyvesant High School.
Similar indexed content