NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 23 pages

Lab report, St. Education tox test, 2002

Machine-extracted title · confidence 22%

Laboratory report from Pace Analytical for the NYC Education Dept, 23 pages, reporting analyses (NELAC) for a project labeled Chemic.

NYC-WTC_000400749–000400771
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Pace Analytical Semees, Inc. irOO Elm Street, Suite 200 ^aceAnalyticar Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612:607.6444

5;? PROJECT: PCDD/PCDF ANALYSES , DATE: January 22, 2002

PAGE: 5 REPORT NO: 02-1052821

I - PCDD/PCDF Quantification and Calculations (Cont.) Each pair of ion rnass^^peaks in the selected-ion-current chromatograms was evaluated manually to B determine if it rnel^jt’fie criteria for a PCDD or PCDF isomer. Areas of all peaks exhibiting correct ion ratios, having;^retention times within the correct windows, and having areas corresponding to concentrations In the range covered by the initial calibration were then summed for calculations of ill total congener concentrations. The toxic equivalence of each sample was calculated using the factorOsted in Table 5,

limit of detection (LOD) based on producing a signal that is 2.5 times the noise level, was calculated for each undetected 2,3,7,8-substituted isomer of any tetra through octa chlorinated congener class. The noise heights used to calculate the detection limits were measured at the M retention time of the specific isomer. The formula used for calculating the LOD is: vis' I ■ ' ' •

Hn X Qis X 2.5 1 LOD = His X W X Rf where: s; LOD Single isomer limit of detection Hn Sum of noise heights at native isomer retention time ■I I Qis Quantity of labeled internal standard His Sum of peak heights for labeled internal standard W Sample amount Rf Response factor

i The recovery of the 2,3,7,8-TCDD-^’Cl4 enrichment efficiency standard and each ’^Cij-labeled • internal standard, relative to either 1,2,3,4-TC-DD-^^Ci2 or'1,2,3,7,8,9-HxCDD-”C,2f was calculated using the following equation:

Ais X Qrs x 100% %R = Rfr x Ars x Qis where:

; %R = Percent recovery of labeled internal standard c ■ ■ Ais = Sum of integrated areas of labeled internal standard CD E Qrs = Quantity of recovery standard 3 o : J Ars = Sum of integrated areas of recovery standard o Q Rfr = Response factor of the specific labeled internal standard relative to the recovery standard TO ■’t ■c Qis = Quantity of the labeled internal standard congener added to the sample m o o Q_ o o Z REPORT OF LABORATORY ANALYSIS o 3 This report shall not be reproduced, except in full, o o 0. without the written consent of Pace Analytical Services. Inc. I O O) O I O z z CITY_21MC100_002896307

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000400754Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000400852

Pace Analytical lab report; project [name]; 19125-0246; 22 pages; general analysis.

Similar indexed content

NYC-WTC_000375748

Laboratory analysis report for ATC project, TEM/analysis, 21 pages.

Similar indexed content

NYC-WTC_000375724

Laboratory results for project 19125-0289 with PGDD/PCDF determinations, 21 pages.

Similar indexed content

Compare copies and versions →