NYC-WTC_000250102
Determination of PCDD/PCDF levels for ATC at NYC site, report for client.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Determination of PCDD/PCDF levels for ATC client at 104 East 25th Street.
NYC-WTC_000250132–000250152OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Pace Analytical Services, Inc. 1700 Elm Street. Suite 200 ^ace Analytical' Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444
PROJECT: PCDD/PCDF ANALYSES DATE: April 5, 2002
PAGE: 5 REPORT NO: 02-1055015
PCDD/PCDF Quantification and Calculations (Cont.) Each pair of ion mass peaks in the selected-ion-current chromatograms was evaluated manually to determine if it met the criteria for a PCDD or PCDF isomer. Areas of ail peaks exhibiting correct ion ratios, having retention times within the correct windows, and having areas corresponding to concentrations in the range covered by the initial calibration were then summed for calculations of total congener concentrations. The toxic equivalence of each sample was calculated using the factors listed in Table 5.
A limit of detection (LOD) based on producing a signal that is 2.5 times the noise level, was calculated for each undetected 2,3,7,8-substituted isomer of any tetra through octa chlorinated congener class. The noise heights used to calculate the detection limits were measured at the retention time of the specific isomer. The formula used for calculating the LOD is:
Hn X Qis X 2.5 LOD = His X W X Rf where:
LOD Single isomer limit of detection . Hn Sum of noise heights at native isomer retention time Qis Quantity of labeled internal standard His Sum of peak heights for labeled internal standard W Sample amount Rf Response factor
The recovery of the 2,3,7,8-TCDD-^ ’Cl4 enrichment efficiency standard and each ’^Cij-labeled internal standard, relative to either 1,2,3,4-TCDD-^^Ci2 or l,2,3,7,8,9-HxCDD-’2Ci2, was calculated using the following equation:
Ais X Qrs x 100% %R = Rfr X Ars x Qis where:
%R = Percent recovery of labeled internal standard Ais = Sum of integrated areas of labeled internal standard Qrs = Quantity of recovery standard Ars = Sum of integrated areas of recovery standard Rfr = Response factor of the specific labeled internal standard relative to the recovery standard Qis = Quantity of the labeled internal standard congener added to the sample
REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in lull, without the written consent of Pace Analytical Services, Inc.
Zri^i CONFIDENTIAL, CITY_21MC100_005760114 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000250137
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000250102
Determination of PCDD/PCDF levels for ATC at NYC site, report for client.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240242
Determination of dioxin and furan levels prepared for ATC Associates in New York, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375748
Laboratory analysis report for ATC project, TEM/analysis, 21 pages.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400852
Pace Analytical lab report; project [name]; 19125-0246; 22 pages; general analysis.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000399555
Laboratory determination report for PCDD/PCDF, ATC 19125-0279, 104 East 25th Street.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375724
Laboratory results for project 19125-0289 with PGDD/PCDF determinations, 21 pages.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400694
Pace Analytical lab report; project 19125-0246, 23 pages.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272110
Laboratory analysis report from Pace Analytical for a site sample related to the Education Department project.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226877
Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.
9 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182790
Laboratory determination report for polychlorinated dibenzo-p-dioxins and furans from samples collected in late 2001.
10 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400723
PACE lab report; 30 pages, NELAC standards, project 19125-0246.
10 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000399532
Laboratory analysis report for PCDD/PCDF on ATC project 19125-0279, 104 East 25th Street.
10 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000375748
Laboratory analysis report for ATC project, TEM/analysis, 21 pages.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000249257
PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400694
Pace Analytical lab report; project 19125-0246, 23 pages.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382417
PACE report: PCDD/PCDF levels for ATC project at 104 East 25th Street.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312330
Attachment with PCDD/PCDF analysis identifiers for NYC-WTC samples.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182790
Laboratory determination report for polychlorinated dibenzo-p-dioxins and furans from samples collected in late 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000250102
Determination of PCDD/PCDF levels for ATC at NYC site, report for client.
Similar indexed content
NYC-WTC_000240242
Determination of dioxin and furan levels prepared for ATC Associates in New York, 2002.
Similar indexed content
Laboratory analysis report for ATC project, TEM/analysis, 21 pages.
Similar indexed content
Pace Analytical lab report; project [name]; 19125-0246; 22 pages; general analysis.
Similar indexed content
NYC-WTC_000399555
Laboratory determination report for PCDD/PCDF, ATC 19125-0279, 104 East 25th Street.
Similar indexed content