NYC-WTC_000245415
ATC letter transmitting IAQ report and scope of work for P.S. 89M, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Indoor air quality measurements report for P.S. 89M school, Feb 2002.
NYC-WTC_000400668–000400671OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan January 31, 2002 Indoor Air Quality Assessment Page 3 P. S. 89M ATCPrpiectNoJ5-19125-0297
Real-Time Environmental Measurements
ATC collected eighty-two (82) sets of real-time environmental measurements consisting of ten (10) outdoors and forty-two (42) inside in the morning (A.M.) and twenty-two (22) inside and eight (8) outside in the afternoon (P.M.). All five floors of the school were surveyed. These results are described below.
Field data sheets are found in the Attachment. Readings began at 8;00 A.M. and concluded after 4:00 P.M.
Temperature
Indoor dry bulb temperature measurements ranged from 68.3°F to 72.2°F (A.M.) and 64.8°F to 71.0°F. Two (2) measurements were below the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). These were readings on the 1^^ floor. The average outdoor temperature was 40.0°F (A.M.)and45.6°F(P.M.).
Relative Humidity
The relative humidity indoors ranged from 25.7 to 38.1 percent (A.M.) and 30.7 to 44.6 percent (P.M.). Four (4) readings in the morning were below the ASPfRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity averaged 55.3 percent (A.M.) and 47.7 percent (P.M.).
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 513 to 1390 ppm (A.M.) and 549 to 999 ppm (P.M.). Two (2) of the morning CO2 measurements were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentrations averaged 484 ppm (A.M.) and 500 ppm (P.M.). Therefore, the maximum acceptable level of CO2 at this location was 1200 ppm (background level -1- 700 ppm). The highest indoor level was measured in classroom 506 which it was occupied by approximately 28 individuals. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration. The 2”^ and 3’'“^ floors of the school building were not occupied during ATC’s assessment.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 0-1 ppm for all readings. These concentrations were below the ASHRAE guideline of 9 ppm. The outdoor CO concentration was 0-1 ppm (A.M.) and 0 ppm (P.M.).
CITY_21MC100_000490658 NYC-WTC_000400670
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000245415
ATC letter transmitting IAQ report and scope of work for P.S. 89M, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359593
Report of lAQ measurements at PS 89M, Warren St., Jan 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400647
Report of IAQ measurements at PS 89M for BOE; January 29, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000404371
Indoor air quality measurements collected for PS 89M re-occupancy prep.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274634
Indoor air quality measurements collected Feb 13, 2002 for P.S. 89M.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382587
Indoor air quality measurements collected on Feb 8, 2002 at P.S. 89M.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382607
Indoor air quality measurements collected on Feb 12, 2002, for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000404359
Indoor air quality measurements at PS 89M for re-occupancy.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000384064
ATC IAQ measurements at P.S. 89M for NYC BOE; report dated Jan 29, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274598
ATC IAQ report for P.S. 89M in Feb 2002, BOE pre-occupancy.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000404395
Indoor air quality measurements collected at PS 89M for pre-occupancy.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000218569
Letter reporting indoor air quality measurements collected at P.S. 89M on February 11, 2002, to evaluate conditions prior to re-occupancy.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000245415
ATC letter transmitting IAQ report and scope of work for P.S. 89M, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382540
Indoor air quality measurements at P.S. 89M prior to re-occupancy.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400647
Report of IAQ measurements at PS 89M for BOE; January 29, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000404371
Indoor air quality measurements collected for PS 89M re-occupancy prep.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274634
Indoor air quality measurements collected Feb 13, 2002 for P.S. 89M.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245442
ATC IAQ measurements report for a NYC school prior to re-occupancy, Feb 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000245415
ATC letter transmitting IAQ report and scope of work for P.S. 89M, 2002.
Similar indexed content
NYC-WTC_000359593
Report of lAQ measurements at PS 89M, Warren St., Jan 2002.
Similar indexed content
NYC-WTC_000400647
Report of IAQ measurements at PS 89M for BOE; January 29, 2002.
Similar indexed content
NYC-WTC_000404371
Indoor air quality measurements collected for PS 89M re-occupancy prep.
Similar indexed content
NYC-WTC_000274634
Indoor air quality measurements collected Feb 13, 2002 for P.S. 89M.
Similar indexed content