NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Indoor air quality assessment, PS 234M, Dec 2001

Machine-extracted title · confidence 30%

ATC IAQ assessment at PS 234M, BOE, December 2001.

NYC-WTC_000396309–000396312
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

• 104 East 25th Street I New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353:8306 ASSOCIATES INC.

December 7, 2001

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Indoor Air Quality Assessment Public School 234M 292 Greenwich Street New York, New York ATC Project No. 15-19125-0279

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of indoor air quality (lAQ) assessments conducted on November 29 - December 1, 2001, at the referenced school. The New York City Board of Education (BOE) requested this assessment to determine indoor air quality prior to reopening the school.

SCOPE OF WORK

ATC conducted this evaluation to assess the basic parameters of temperature, relative humidity, carbon dioxide (COj) and carbon monoxide (CO).

Total volatile organic compounds (TVOCs) and respirable particulates (PM2.5) were also measured.

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists, of ATC’s New York City office, conducted the assessment. ATC’s findings and conclusions are based on a visual inspection, real-time environmental measurements and conditions present in the school at the time of the assessment.

ATC measured temperature, relative humidity, CO, and CO with a Q-Trak® Model 8551, manufactured by TSI, Inc. ,

ATC measured concentrations of respirable particulates with a Dust-Trak® Aerosol Monitor Model 8520, manufactured by TSI, Inc.

ATC measured concentrations of TVOCs using a RAE Systems, Inc. MiniRAE® photoionization detector (PID).

The assessment was performed consistent with generally accepted indoor air quality assessment practices. As with all such assessments, there were inherent limitations created by constraints of

CITY_21MC100_002891117

NYC-WTC_000396309

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000396309Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000370529

Indoor air quality measurements collected March 21, 2002 at the referenced school.

Similar indexed content

Compare copies and versions →