December 12, 2001
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Hydrocarbons & Metals
P. S. 234M
ATC Project No. 15-19125-0279
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for metals and
hydrocarbon compounds conducted on November 29, 30 and December 1, 2, 2001, at the
referenced school. The New York City Board of Education (BOE) requested this sampling as
part of a program to determine indoor air quality prior to reoccupancy of the building.
On each day, ATC collected four (4) samples each for hydrocarbon compounds (HC) and metals
at specified locations. Samples were collected for a minimum of seven (7) hours. For the HC,
ATC used activated coconut shell charcoal tubes connected to battery-powered sampling pumps
at a flow rate of 0.2 liters per minute (1pm). Metal samples were collected using mixed cellulose
ester filters and pumps set to draw 2.0 1pm. Pumps were calibrated before and after each
sampling period. Three (3) samples for each analysis were collected inside the building and one
(1) was collected outdoors. One blank filter and tube were also submitted on each day.
The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene
Association-accredited laboratory in Reading, PA. Analysis of the HC was performed by
capillary gas chromatography/flame ionization detection (NIOSH Methods 1003,. 1005, 1022,
1300, 1500, 1501). Each sample was analyzed for a panel of sixteen (16) specific HC compounds.
In addition, two non-identified peaks. A- hydrocarbons and B-hydrocarbons, were reported. The
A-hydrocarbons are those, such as gasoline or light alcohols, with boiling points less than that of
benzene (176°F). The B-hydrocarbons are those, such as mineral spirits or petroleum naphtha,
with boiling points greater than that of benzene.
Analysis of the metal samples was performed inductively coupled argon plasma/atomic emission
spectroscopy according to NIOSH Method 7300M. Each sample was analyzed for eleven (11)
metals. Copies of the analytical reports are attached.
Four different sampling locations were selected on each day. They were as follows:
November 29 - Cafeteria (SE), Library (2'“’ floor SE), Room 305 (SE), Outdoors (E)
November 30 - Room 111 (SW), Room 229 (SW), Room 329 (SW), Outdoors (N)
December 1 - Room 122, Room 222, Room 322, Roof by HVAC intake
December 2 - 1“ floor hall by Exit 1,2"“^ floor hall by Exit 1, 3'''’ floor hall by Exit 1, Roof