Dust and air sampling for PS 234M, Oct 2001

Machine-extracted title · confidence 46%

Dust, bulk and ambient air sampling for asbestos at PS 234M; site visit notes.

NYC-WTC_000395996–000395997
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Oatc ASSOCIATES INC 600 West Cummings Park, Suite 6500 Woburn, Massachusetts 01801-6350 www.atc-enviro.com 781.932.9400 Fax 781.932.6211

October 3, 2001

Mr. Bernard P. Orlan New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Dust, bulk and ambient area air sampling for asbestos at P.S. 234M

Dear Mr. Orlan:

At your request, ATC Associates, Inc. representatives Mr. Andreas C. Andreou (NYC-DEP asbestos investigator #82683 & NYS-DOL asbestos inspector / air sampling teclmician certificate #AH 93-18603), Mr. Yiannis Efstathiou (NYC-DEP asbestos investigator #82244 & NYS-DOL asbestos inspector / air sampling teclmician certificate #AH 96-10905) and Mr. Wagdi Abdelshahid (NYS-DOL asbestos inspector certificate #AH01-02278) visited P.S. 234M located at 292 Greenwich Street, New York, NY 10013 on October 2"'*, 2001. The purpose of the site visit was to perform a dust and ambient area air sampling to be analyzed for asbestos content tliroughout the interior of the school building and bulk sampling of debris on the roof as per a NYC-BOE representative.

As per NYC-BOE representative request, a total of fifty (50) dust samples, using 3M scotch tape and a glass slide, and twenty (20) ambient area air samples were collected tliroughout the school building. Also, tliree (3) debris bulk samples were collected from die roof.

Also as per the NYC-BOE representative request, all twenty (20) ambient area air samples were analyzed utilizing Transmission Electron Microscopy (TEM). Analytical results indicated that none of the collected ambient area air samples contain any asbestos structures. See attached laboratory report and results.

All fifty (50) collected dust samples and the three (3) bulk samples were analyzed utilizing Polai’ized Light Microscopy (PLM).

Analytical results indicated that none of the collected dust samples contain any asbestos fibers.

Analytical results also shown that two (2) out of the three (3) debris bulk samples collected from the roof contain only traces of asbestos.

The dust, bulk and ambient area air sampling performed was limited to testing for asbestos in the ■ locations indicated by a NYC-BOE representative.

CITY_21MC100_002890785

NYC-WTC_000395996

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000395996Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →